Glenayre Document Number: 9110.00148
RL-903 Receiver
Issue 1, Rev. C: 12/10/96
INSTALLATION AND SETUP
4
INSTALLATION AND SETUP
This manual contains setup information for the receiver. For a broader view of setup, refer
to the system manual.
4.1
Precautions and Hazards
Caution
PC boards within this assembly use static-
sensitive
components.
Follow
IC-handling
precautions.
4.2
Test Equipment and Tools Required
Most internal adjustment can be performed with the receiver chassis pulled forward and
with the lid removed.
The receiver's RF and l.o. sections should not need realignment unless poor operation is
indicated or if the receive frequency has been changed by more than one MHz.
Table 4-1,
Test Equipment Required,
shows required test equipment for setup. Common hand tools are
also required.
Table 4-1 Test Equipment Required
item
characteristic
service monitor
to 1 GHz, IFR model 1200S or equivalent
frequency counter
to 1 GHz
digital voltmeter
Beckman model 330 or equivalent
audio distortion analyzer
capable of measuring audio distortion to 3000 Hz, Sinadder or equivalent
power supply
+12 Vdc at 3 A
(optional) spectrum analyzer
capable of displaying up to 1 GHz
(optional) RF millivoltmeter
capable of reading 0 dBm at 1 GHz
QPN 263-0305-002
receiver I/O board for accessing I/O signals
slotted alignment tool
Johanson 8777
4.3
Component and Adjustment Locations
Figure 3-3, Top View of Internal Assemblies,
shows the locations of pc boards.
Print Date: 12/05/96
Copyright © 1996 Glenayre
Page: 4-1