Step 8:
Install outer shell body in tool
600-236
. Ensure the male polarization key of the shell is engaged
into the female key locator on the tool. Mate tool into cable assembly. Ensure the polarization
key of the outer insulator is lined up with the polarization key of the shell body per
Figure 3
.
Use insert tool
600-242
to slide cable assembly into shell body using
600-236
as a guide per
Figure 4
. Ensure crimp bushing is fully seated.
Figure 3
Figure 4
Step 9:
Use crimp tool
Daniels HX4 M22520/5-01
with die
Y143.
Load contact assembly into side A.
Locate the step at the back of the contact. Ensure the step is flush with the top face of the die,
crimp contact.
Key