background image

 

AI85112-02S                                    Page 

2

 of 

4

 

 
 

Step 2:  

Remove cable jacket

 (0.590”) 

to expose the braid shield. 

 

             

 

Step 3: 

 

Flare cable braid to expose the twisted pair wires with aluminum foil shields. Flare wire bundle 
with aluminum foil shields and trim the middle filler as close to the jacket as possible. 

                        

   

 

 

 

     

 

 

 

 

Step 4:  

Identify cable twisted pair color orientation to match 

Figure 1

. Unwrap foil around one pair.

 

Remove insulation of the conductors to 

(0.115”)

.  Install inner contacts over conductor until 

fully seated. Make sure the conductor is visible through the inspection hole. Crimp the inner 
contacts using crimp tool 

M22520/2-01

 and positioner 

Daniels

 

P/N K1906

, Setting

 #3

 for 

26 

AWG

. Re-wrap foil tightly around the wire pair. Use Kapton tape to hold the foil in place. Trim 

excess tape and foil to expose wire insulator. No more than 0.100” of insulator should be 
exposed. Ensure foil does not cover base of contact.  

       

     

 

 

     

 

                     

 
 
 
 
 
 
 
  

Reviews: