AI85112-02S Page
2
of
4
Step 2:
Remove cable jacket
(0.590”)
to expose the braid shield.
Step 3:
Flare cable braid to expose the twisted pair wires with aluminum foil shields. Flare wire bundle
with aluminum foil shields and trim the middle filler as close to the jacket as possible.
Step 4:
Identify cable twisted pair color orientation to match
Figure 1
. Unwrap foil around one pair.
Remove insulation of the conductors to
(0.115”)
. Install inner contacts over conductor until
fully seated. Make sure the conductor is visible through the inspection hole. Crimp the inner
contacts using crimp tool
M22520/2-01
and positioner
Daniels
P/N K1906
, Setting
#3
for
26
AWG
. Re-wrap foil tightly around the wire pair. Use Kapton tape to hold the foil in place. Trim
excess tape and foil to expose wire insulator. No more than 0.100” of insulator should be
exposed. Ensure foil does not cover base of contact.