background image

Specifications

Features

7051 INSTANT 3 Ltr WH - 3 KW/4.5KW

Type

Electric Instantaneous Water Heater

Rated Capacity in Ltr. 

3

3

Mounting

Vertical

Rated voltage in volts & frequency in Hz.

230V, 50Hz, A.C

Rated power input in Watts

3000

4500

Rated Pressure

6 Bar

Indicator Lamps

Green-Thermostat Operation

Red-Cutout Operation

Safety Valve

95-109 p.s.i

Inner Container

SS 304

Outer body

Polypropylene

Heating Element

Heavy Duty Copper

Star Rating

ISI

Reheating Time in Mins. To raise 50°C (Max.)

NA

Mean hot water output temp. 

o

C (Min.)

75

Mixing Factor Maximum (%)

NA

Water Proof Degree

IPX1

Weight Empty (Kg.)

2.6

2.7

Note: The dimension may vary from model to model without affecting the capacity. Due to 

continues improvement in product, specifications are subject to change without prior notice.

Troubleshooting

#

Failure

Reason

Treatment

1

Water Heating 

takes longer time 

than Instruction 

manual

Scaling on the Heating 

element cause slower 

water heating thermometer.

Get the Heating element  

de-scaled from authorised 

service person or replace 

with genuine spare parts 

recommended by company
Measure the temperature of 

water using Adjust the flow rate 

at 3 Ltrs/min

Low voltage at certain 

places

Check the voltage at customer's 

place

2

Equipment creates 

abnormal Noise

High voltage fluctuations, 

Hard water

Recommend Spare Heating 

element with low watt density 

(8W/cm)

Equipment creates 

hissing Noise

Due to scaling on Heating 

Element

descaling Heating element

Instant Water Heater Manual.indd   5

9/19/2019   6:06:52 PM

Summary of Contents for WH-7051

Page 1: ...ELECTRIC INSTANTANEOUS WATER HEATER WH 7051 3 Ltr 3 KW 4 5 KW Helpline 9266655555 E mail service glenindia com info glenindia com Instant Water Heater Manual indd 1 9 19 2019 6 06 52 PM...

Page 2: ...ter heater have many years of trouble free service To enable your electric water heater to give you many years of perfect trouble free service we recommend you to follow the instructions of the servic...

Page 3: ...ply system by means of a 1 2 BSP pipe fitting 6 Care to be taken to avoid damage caused by applying excessive force while connecting Electrical Connections Refer wiring diagram to check electrical con...

Page 4: ...on of the water heater should be done by qualified personnel only When newly installed make sure that the water flows freely from the outlet tap or spout before electric supply is switched on Inlet wa...

Page 5: ...without affecting the capacity Due to continues improvement in product specifications are subject to change without prior notice Troubleshooting Failure Reason Treatment 1 Water Heating takes longer t...

Page 6: ...alve closed Open the inlet valve 6 User gets mild shock when using Water heater Improper earthing at customers place Check for proper earthing if not then suggest customer to do it properly 7 Outlet w...

Page 7: ...OUT pipes Heating Element and Safety valve be de scaled at least once in 6 months through proper Glen service only This helps in Improving product life 10 As per the safety norms Thermostat Cut out ar...

Page 8: ...authorised by the company The serial no has been deleted defaced or altered Any modification or alteration of any nature is made in the product Normal wear tear of the product is not covered under wa...