Safety Devices
A. Safety Valve
In - built safety (pressure relief valve) is set to operate 6 Bar Service the safety valve
at least once in 6 months Glen service persons. Close inlet water supply. Remove
dirt / scales from the water connection side. Push rubber disk gently to ensure it is
not stuck. Do not tamper with the sealed screw other wise pressure setting will get
disturbed. Fix back after replacing old fibre washer. Check for any leakage before
switching on electric supply
B. Thermal Cut-Out
Stem type nonself-resetting Thermal Cut out set to operate at temperature below 96°c
and disconnects electrical supply for extra safety. Please contact qualified service
personnel in such an event.
C. Thermostat
Stem type self-resetting; Automatic Resetting type, ON/OFF indication by red lamp.
Maintenance & Cleaning
Installation is to be done by qualified personnel only, Glen Appliances Pvt. Ltd. cannot
be held responsible for the damages caused by wrong installation, faulty material, using
substandard water or for not following instructions included in this instruction manual,
particularly:
•
Installation of the water heater should be done by qualified personnel only
•
When newly installed, make sure that the water flows freely from the outlet tap (or
spout) before electric supply is switched on.
•
Inlet water line should be continuously open when water heater is in use except
when it is being serviced.
•
The temperature of the water can be regulated by controlling the flow through hot
water stop cock.
•
When no more hot water is required the electric supply must be switched ‘OFF’
before the hot water stopcock is closed.
•
Switch off water heater when not in use.
•
The Green indicator lamp which is ON during the normal operation, turns OFF when
the thermal cut-out is activated. Contact qualified service personnel in this event.
•
Use pressure reducing valve in case operating pressure In the water heater is higher
than 6 bar.
•
The electrical connection should be in accordance with the instruction given refer
page 3.
•
The safety valve needs to be service at least once in 6 months.
Warning : Do not switch on the water heater if there is a possibility that
water in the heater is frozen.
1. Check that the electric data shown on the date plate corresponds to those
of the electric supply available.
2. Minimum contact separation of circuit breaker 3mm.
Instant Water Heater Manual.indd 4
9/19/2019 6:06:52 PM