Masport Geneva
2
Owners Installation and Operation Manual
Page 9
CLEARANCES TO COMBUSTIBLES
Minimum clearances listed above must be
maintained. Also ensure that you have left
clearance for servicing and that that the proposed
termination location is correct.
LOCATING YOUR STOVE
IMPORTANT: This appliance's venting system
is room sealed, which means that there should
be no provision to allow room air to be used in
the combustion process.
VENTING
Note: Only approved venting systems may
be used with the Geneva
2
.
PLANNING YOUR VENT INSTALLATION
This type of direct vent system may terminate in
one of two ways: Vertical termination using a
vent cap, or Horizontally using a wall termination.
There are limitations to the vertical and/or
horizontal lengths. When calculating the length
of the vent pipe from the outlet of the appliance
to termination, allow for ceiling thickness,
vertical rise in the attic or second story and
sufficient vertical height above the roof.
Fire stops are required at each floor level the
vent passes through.
When carrying out vertical installations that
require 45° elbows add additional pipe to allow
for the offset.
Installation Instructions
MODEL
Geneva
2
A Side Wall to unit side
275mm
B Back wall to unit back
100mm
C Corner to side wall
50mm
REAR VENT—SNORKEL TERMINATION
'()('*' +,%#(
- %( ,