www.gdts.one
451905.66.07 · FD 9912
EN-21
DHW 300VD+
English
8.2
Energy consumption during heat-up time
kWh
4.25
8.3
Power consumption during stand-by period
5
W
29
8.4
Electric energy consumption
W
EL-TC
according to EN 16147 cycle XL
kWh
5.78
8.5
COP according to EN 16147 cycle XL
3.3
8.6
Reference domestic hot water temperature
°C
55.9
8.7
Maximum usable domestic hot water quantity
litres
421
8.8
Load profile
XL
8.9
Water heating energy efficiency
ŋ
wh
%
137
1. At temperatures below 7 °C ± 1 °C, the heating element is automatically switched on and the heat pump module off.
2. At a distance of 1m (free-standing installation or installation without exhaust air duct or 90° pipe bends on outlet side).
3. Heating up of the nominal volume from 10 °C to 55 °C at an air intake temperature of 15 °C and a relative humidity of 70 %
4. The information is valid for a new device with clean heat exchangers
5. With an air intake temperature of 15 °C and relat. humidity of 70 %