Gas Hob
Faulty ignition (Automatic ignition)
Customer states no ignition to burner/s
NO
YES
YES
NO
YES
NO
NO
YES
Is more than one
burner affected?
Can customer see a
spark at the burner?
Send engineer order
electrode and ignition
switch ( micro switch)
Ask customer to clean
and make sure burner
skirt and cap are fitted
correctly. If this does
not work.
Are all four
burners affected
Has customer check
electric supply to
hob?
Send engineer and
order spark
generator
Send engineer order
electrodes required and
Ignition switch (micro switch)