11.2 Device information, domestic
hot water cylinder
Type and order code
MDHW 232
MDHW 335
10 Technical data
10.1 Material
Enamelled steel complying with
DIN 4753
Enamelled steel complying with
DIN 4753
10.2 Cylinder volume
litres
220
355
10.3 Nominal volume
litres
199
330
10.4 Max. operating overpressure
bar
10
10
10.5 Dimensions
without connections
H x W x L mm
1400 x 600 x 600
2100 x 600 x 600
10.6 Connections
Cold water / domestic hot water / circulation
inches
R 1“ external thread / R 1“external
thread / R 3/4“ external thread
R 1“ external thread / R 1“external
thread / R 3/4“ external thread
10.7 Heat exchanger area
m²
3.21
3.6
10.8 Heat losses according to DIN EN 12897 / class
kWh / 24 h / -
1.15 / B
1.63 / B
10.9 Energy efficiency class domestic hot water preparation / drawing cycle
A / XL
10.10 Usable domestic hot water quantity in accordance with DIN EN 16147
(Cylinder temperature 55 °C)
litres
305