background image

Page 22

TERMS AND C

ONDITIONS

Gledhill

 (Water Storage) 

Ltd

AMD. JUNE 2008

CONDITIONS OF SALE & GUARANTEE TERMS

1.

Gledhill (Water Storage) Ltd (“We” or “Gledhills”) only do business upon the Conditions which appear below 

and no other.  Unless we so agree in writing these Conditions shall apply in full to any supply of goods by us to 
the exclusion of any Conditions or terms sought to be imposed by any purchaser.  These Conditions of Sale and 
Warranty Terms override those which are contained on the Invoice Forms and all Sales are now subject to these 
Conditions of Sale and Warranty terms only.
2.

PRICE

Once an order or call off has been accepted the price will be held for three months but if delivery is extended 
beyond that period at the customer’s request, then we reserve the right to amend the price when necessary.
  
The company reviews its pricing annually to adjust for changes in our cost base.  We reserve the right to alter prices 
at any time for severe movements in raw materials (mainly copper and steel).  If there is to be a change we will give 
customers at least four weeks notice but anything delivered after that date will be at the revised price.  An order 
may not be cancelled or varied after acceptance without the written consent of the company.  Such cancellation or 
variation shall be subject to such reasonable charges as may be appropriate.
3.

SPECIFICATION

The goods are supplied in accordance with the Specifications (if any) submitted to the Purchaser and any additions 
and alterations shall be the subject of an extra charge.  Any goods not so specified shall be in accordance with our 
printed  literature  or  the  literature  of  any  of  our  component  suppliers  (subject  to  any  modifications  made  since 
publication).  If we adopt any changes in construction or design of the goods, or in the specification printed in our 
literature, the Purchaser shall accept the goods so changed in fulfilment of the order.
4.

PAYMENT

The invoice price of goods shall be payable within 30 days of despatch by us of our invoice for the goods or such 
longer time as may be stated by our quotation or invoice.  If we receive payment in full on or before the due date we 
will allow an appropriate settlement discount except where we have quoted a special net price.  If payment is not 
received in full on or before the due date we shall be entitled in addition to the invoice price to:
(i)

payment of a sum equal to any increase in the copper price supplement applicable to the particular goods 
sold between the date of receipt of order and the date of receipt of payment in full; and 

(ii)

interest on any part of the invoice price unpaid after the due date at the rate of 3% per annum over the base 
rate for the time being of HSBC Bank plc.

5.

TIME

We give estimates of delivery dates in good faith and time of delivery is not nor shall be made of the essence of any 
contract nor shall we be liable for any loss or damage occasioned by delay in delivery.
6.

DELIVERY

We deliver free normally by our own vehicles within 25 miles of any of our manufacturing depots.  Delivery to any 
place more than 25 miles from one of our manufacturing depots may be subject to our quoted delivery charges.  We 
reserve the right to make delivery of goods contained in one order by more than one consignment and at different 
times.  Where a period is agreed for delivery and such period is not extended by our Agreement, the Purchaser shall 
take delivery within that period.    If the Purchaser fails to take delivery, we shall be entitled at the Purchaser’s risk and 
expense to store the goods at the Purchaser’s premises or elsewhere and to demand payment as if they had been 
despatched.  Off loading at point of delivery shall be the responsibility of and be undertaken by the Purchaser.
7.

SHORTAGES OR DAMAGE

Goods must be inspected before signature of delivery note and any damage, shortage or discrepancy noted on the 
delivery note and the goods returned on the same vehicle.  The buyer must also give us immediate written notice of 
the damage, shortage or discrepancy so that we may prompt investigation.
8.

RETURN OF GOODS

Goods  may  not  be  returned  to  the  Company  except  by  prior  written  permission  of  an  authorised  officer  of  the 
Company  and  such  return  shall  be  subject  to  payment  by  the  Purchaser  of  handling  and  re-stocking  charges, 
transport and all other costs incurred by the Company.
9.

COMPANY LIABILITY AND GUARANTEE

9.1. Subject to the terms of these Conditions of Sale and Guarantee Terms Gledhills provide Guarantees in respect 

of specific products as set out in this clause.

9.2. Each Guarantee is strictly conditional upon the following:-
9.2.1. Complaints must be given to us immediately, before any action is taken, as responsibility cannot be accepted 

if repairs or renewals are attempted on site without our written approval.

9.2.2. The unit has been installed in accordance with our installation and service instructions and all relevant codes 

of practice and regulations in force at the time of installation.

9.2.3. All necessary inlet controls and safety valves have been fitted correctly. 
9.2.4. The unit has only been used for the storage of potable water supplied from the public mains.
9.2.5 Where  appropriate  the  unit  has  been  regularly  maintained  as  detailed  in  the  installation  and  service 

instructions

9.2.6. Defects caused by corrosion or scale deposits are not covered by any Guarantee.
9.2.7. Where we agree to rectify any defect we reserve the right to undertake the work on our own premises.
9.3. Guarantees are provided in respect of specified goods supplied by Gledhills as follows:-

(a) Domestic and Commercial Open Vented Cylinders and Tanks.
The copper storage vessel is guaranteed for ten years and if it proves to be defective either in materials or 
workmanship, we will either repair or supply replacement at our option with the closest substitute in the case 
of any obsolete product to any address in Great Britain.
(i)    free of all charge during the first year after delivery by us.
(ii) thereafter at a charge of one-tenth of the then current list price and any copper price supplement and 

delivery charge during the second year after delivery by us and increasing by a further one-tenth on the 
second and subsequent anniversary of delivery by us.

(b) Domestic Mains Fed Products [Primary Stores]
The copper storage vessel is guaranteed for five years and if it or any integral pipework as part of the storage 
vessel  assembly  proves  to  be  defective  either  in  materials  or  workmanship,  we  reserve  the  right  to  either 
repair or supply replacements or the closest possible substitute in the case of any obsolete product and will 
collect and deliver to any address in England, Wales and Scotland (excluding all Scottish Islands).
(i) free of all charge during the first year after delivery by us.
(ii) thereafter  at  a  charge  of  one-fifth  of  the  then  current  list  price  or  any  copper  price  supplement  and 

delivery charge during the second year after delivery by us increasing by a further one-fifth on the second 
and subsequent anniversary of delivery by us.

(c) Integrated Boiler and Storage Vessel Products and Stand Alone Boilers
In the case of the GulfStream range of products and the Gledhill boiler range of products,  Gledhill guarantees 
the heat exchanger (boiler) for material and construction faults for two years.  THE RESPONSIBILITY FOR THE 
EXECUTION OF THIS GUARANTEE LIES WITH THE INSTALLER.
The guarantee becomes null and void if the appliance is used incorrectly, or in the event of proven negligence 
or  incorrectly  implemented  repairs  OR  FAILURE  TO  CARRY  OUT  THE  RECOMMENDED  INSPECTION/
MAINTENANCE
.  The guarantee also becomes null and void if changes are made to the appliance without our 
knowledge, or if the serial number on the appliance is removed or made illegible.

The annual service must be carried out by a competent 
installer  in  accordance  with  the  advice  given  by 
Gledhill and using Gledhill approved parts.
(d) Stainless Steel Unvented Cylinders
Gledhill guarantee the components including controls, 
valves and electrical parts for two years from the date 
of purchase.  IT SHOULD BE NOTED THAT THE FACTORY 
FITTED  TEMPERATURE  AND  PRESSURE  RELIEF  VALVE 
MUST  NOT  BE  REMOVED  OR  ALTERED  IN  ANY  WAY 
OR THE GUARANTEE WILL NOT BE VALID.  GLEDHILL 
WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL 
LOSS OR DAMAGE HOWEVER IT IS CAUSED. 
The  guarantee  for  the  stainless  steel  vessel  is  for 
twenty five years if the original unit is returned to us 
AND PROVIDED THAT:
(i) It has been installed as per the Design, Installation 

&  Servicing  Instructions,  relevant  standards, 
regulations and codes of practice.

(ii) It has not been modified, other than by Gledhill.
(iii) It  has  not  been  subjected  to  wrong  or  improper 

use or left uncared for.

(iv) It  has  only  been  used  for  the  storage  of  potable 

water.

(v) It has not been subjected to frost damage.
(vi) The benchmark log book is completed after each 

annual service.

(vii) The unit has been serviced annually.
It should be noted that the guarantee does not cover:
-

the effects of scale build up

-

any labour charges associated with replacing the 
unit or  parts.

If  the  stainless  steel  vessel  proves  to  be  defective 
either  in  materials  or  workmanship  we  reserve  the 
right  to  either  repair  or  supply  replacements  or  the 
closest possible substitute in the case of any obsolete 
product and will collect and deliver to any address in 
England, Scotland and Wales (excluding all islands):
(i) free of charge during the first year after delivery by us.
(ii) thereafter  at  a  charge  of  one  twenty  fifth  of  the 

then  current  list  price  during  the  second  year 
after  delivery  by  us  and  increasing  by  a  further 
one  twenty  fifth  on  the  second  and  subsequent 
anniversary of delivery by us.

ACTION IN THE EVENT OF FAILURE
If  the  stainless  steel  cylinder  develops  a  leak  we  will 
ask for a deposit against the supply of a new one.  This 
will be refunded if the failure is within the terms of the 
warranty when it has been examined by us.
(e) Solar Panels and ancillary equipment
Gledhill  provides  a  five  year  warranty  for  defects  in 
the  collectors  (except  broken  glass  and  collector 
accessories  eg  metal  edgings).    If  the  collector 
demonstrably fails to meet one of the requirements of 
the standard DIN 4757 part 3 we will replace it free of 
charge based on the date of invoice.  We can not be 
responsible for damage caused by mechanical stress 
and/or changes caused by weather related influences.  
The  warranty  excludes  minor  surface  damage  that 
does  not  affect  performance  or  malfunction  due  to 
improper assembly or installation.
Please note:
-

Installation  must  have  been  carried  out  by  a 
licensed specialized company (heating contractor 
or  plumber)  following  the  version  of  installation 
instructions in force.

-

Gledhill  or  its  representative  was  given  the 
opportunity  to  check  complaints  on  site 
immediately after any defect occurred.

-

Confirmation  exists  that  the  system  was 
commissioned  properly  and    that  the  system 
was  checked  and  maintenance  was  performed 
annually  by  a  specialised  company  licensed  for 
this purpose.

(f) Components  of  our  products  other  than 
Storage Vessels and Integral Pipework.
We will either extend to the purchaser the same terms 
of  warranty  as  we  are  given  by  the  manufacturer  of 
the component or if the manufacturer does not give 
any warranty, replace free of charge any component 
which  becomes  defective  within  two  years  after  the 
date of the delivery by us and is returned to us at the 
purchaser’s expense but we shall not meet the cost of 
removal  or  shipping  or  return  of  the  component  or 
any  other  cost  charges  or  damages  incurred  by  the 
purchaser.
If the appliance manufactured by Gledhill incorporates 
a factory fitted scale inhibitor then during the period 

Summary of Contents for BMA 200 SP-SOL

Page 1: ...ons before installation Model Numbers BMA 200 SP SOL BMA 220 SP SOL BMA 240 SP SOL BMA 260 SP SOL BMA 280 SP SOL BMA 300 SP SOL All models comply with the water heater manufacturers specification for integrated thermal stores A sealed system central heating and mains pressure hot water supply appliance with thermal store designed specifically for use with solar energy ISSUE 5 06 08 ...

Page 2: ...eme as an option to notifying the Local Authority directly Similar arrangements will follow for Scotland and will apply in Northern Ireland from 1st January 06 CORGI operates a Self Certification Scheme for gas heating appliances These arrangements represent a change from the situation whereby compliance with theBuildingRegulationswasacceptediftheBenchmarkLogbookwascompletedand this was then left ...

Page 3: ...S6 are connected to the appliance control PCB which operates all theheatingandhotwaterfunctionsasthebasic BoilerMate appliance Sensors T1 T2 and T3 are connected to the Danfoss controller and operate all the solar functions SensorT3providesahightemperatureinterlock to de activate the solar pump at a temperature of 90 C in the store Although sensors T3 and T2 are wired in to the solarcontrollerthec...

Page 4: ...beorderedasanoptionalextrabut will need fitting on site by the installer Note If the summer towel rail circuit is required this willneedtobeaseparatezonedcircuitfromthe heating circuit complete with its own time and temperature controls The standard manual fill model BoilerMate A ClassSPSOLapplianceisshown Aballvalveand overflowareavailableasanoptionalextraatthe time of order If required these sho...

Page 5: ...pth F BMA 200 SP SOL 1980 660 630 BMA 220 SP SOL 1980 660 630 BMA 240 SP SOL 2175 660 630 BMA 260 SP SOL 2175 710 680 BMA 280 SP SOL 2175 740 710 BMA 300 SP SOL 2085 810 780 The above dimensions include the 100mm high installation base and allow space for installation maintenance of the appliance only The height shown for the 200 220 models also allowsfortheinstallationoftheF Ecistern with no ball...

Page 6: ...s easier if all pipes protrude vertically in the cut out area shown Compression or push fit connections can be used All pipe positions are approximate and subject to a tolerance of 20mm in any direction A 15mm cold water supply and a 22mm warning overflow pipe may also be required for the separate feed and expansion cisterns if these are located in the appliance cupboard Note All dimensions are sh...

Page 7: ...rom any direction It is easier if all pipes protrude vertically in the cut out area shown Compression or push fit connections can be used All pipe positions are approximate and subject to a tolerance of 20mm in any direction A 15mm cold water supply and a 22mm warning overflow pipe may also be required for the separate feed and expansion cisterns if these are located in the appliance cupboard Note...

Page 8: ...ude vertically in the cut out area shown Compression or push fit connections can be used All pipe positions are approximate and subject to a tolerance of 20mm in any direction A 15mm cold water supply and a 22mm warning overflow pipe may also be required for the separate feed and expansion cisterns if these are located in the appliance cupboard Note All dimensions are shown in mm and are to the ce...

Page 9: ... flow collector connection from panel 28 Remote solar panel sensor T1 cable 29 Solar return sensor T2 30 Solar overheat sensor T3 31 Solar circuit pump UPS 15 60 high temp 32 Solar controller 33 User control panel clock 34 Appliance control board 35 Electrical DIN rail 36 Solar expansion vessel connection fitted with pressure gauge 37 100mm high installation base Optional Equipment Hot and cold wa...

Page 10: ...licone 2 Bl Bl R 2 x 3kW Heating Elements R SL H E E PE IH 2 5 mm SID Silicone 2 2 5 mm SID Silicon 2 2 5 mm SID Silicone 2 4 0 mm SIF Silicone 2 2 5 mm SIF Silicone 2 2 5 mm SIF Silicone 2 2 5 mm SIF Silicone 2 2 5 mm SIF Silicone 2 2 5 mm SID Silicone 2 Dedicat Remove link to fit room stat 3 WAY BUS BAR C1 A1 A2 2 4 1 3 2 5 mm SID Silicone 2 2 5 mm SID Silicone 2 3 1 2 4 ISSUE No 4 APPROVED DATE...

Page 11: ...Speed Y Br G Wh S5 S6 Duplex Sensor must fitted into S6 pocket i e above both V3 V2 valves Duplex Sensor must be fitted in top saftey overheat pocket and secured G Y Or Wh B B J34 J5 J30 J31 J9 1 Br Br B B R Or R Or Dedicated Solar Zone Sensor Solar Collector Sensor fitted in the panel sensor pocket provided by manufacturer Minimum pocket size 8mm 8 7 6 5 A B C D E DRG NAME DRG SIZE JOB NAME TITLE...

Page 12: ...n Expansion Vessel PRV 0 20 100 120 40 80 60 0 2 10 4 8 6 Temperature Gauge and Check Valve This component arrangement is provided with the SOL appliance and must be mounted vertically on the connection provided No isolation valve should be installed between the solar circuit and the safety valve pressure reducing valve Note No valves should be fitted on the pipework between the solar collector an...

Page 13: ... will not be affected by holding off the boiler and operates independently of channel 1 If a high hot water demand is expected or the appliance runs out of hot water due to poor solar gains the setting of Channel 1 can be overridden which will bring on the boiler and ensure hot water is made available Dependant on use weather the off times suggested above can be adjusted as necessary to ensure ade...

Page 14: ...artonatemperaturedifferentialof5 Candthe pump will run until the temperature differential is below 2 C The controller will also exercise the pump for 1 minute every 14 days to help stop it sticking if it has not been used Solar Heat Output Gives the performance of the solar heat installation Thefigureiscalculatedonthebasis of the difference between the temperature in the solar collector and the te...

Page 15: ...p model connections Set speed higher No alarm temperature flashes Pump runs indicates high temperature Pump does not run Set speed higher Pump or pump output defective For any further technical information assistance regarding this product please ring the Gledhill Technical helpline on 08449 310000 Solar collector Thermal Store 0 95 120 40 Operating range Sensor fault alarm Sensor fault alarm Sens...

Page 16: ... to 4 bar WATCHING THE LEVEL OF FLUID IN YOUR BOTTLE and adding more antifreeze solution if required When a pressure of 4 bar is achieved close the filling point on the fill and flush valve at the SAME time switch off the power at the RCD safety device Now leave the system under this pressure for at least 30 minutes Check the system for leaks including the roof connections If after 30 minutes the ...

Page 17: ...l valve Vemco FT206 All 11 1 x 6 kW switch immersion heater Wardtec XB468 All 12 Bottom store sensor Tasseron GT198 All 13 Middle store sensor Tasseron GT198 All 14 Top OHT store sensor Tasseron GT199 All 15 Main PCB controller Argus Vision XB442 All 16 Front panel user membrane All 17 Internal fuses circuit protection MCB Single Pole 6A x 1 XB449 All MCB Single Pole 16A x 2 XB450 All 18 Switch co...

Page 18: ...Page 18 1 2 3 4 24 5 6 12 13 7 8 9 10 11 15 16 20 19 17 21 23 30 31 29 27 28 26 14 18 22 SHORT PARTS LIST INSTALLATION 34 ...

Page 19: ...Page 19 ...

Page 20: ...Page 20 ...

Page 21: ...Page 21 ...

Page 22: ...in materials or workmanship we will either repair or supply replacement at our option with the closest substitute in the case of any obsolete product to any address in Great Britain i free of all charge during the first year after delivery by us ii thereafter at a charge of one tenth of the then current list price and any copper price supplement and delivery charge during the second year after del...

Page 23: ...ject to of any other contract between the Purchaser and us which at the time of payment of the full price of the goods sold under this contract have been delivered to the Purchaser but not paid for in full c until property in the goods supplied hereunder passes to the Purchaser in accordance with paragraph 2 above i the Purchaser shall hold the goods in a fiduciary capacity for us and shall store ...

Page 24: ...Thecodeofpracticefortheinstallation commissioning servicingofcentralheatingsystems ...

Reviews: