The Buffer store is insulated to a very high standard using high density
HCFC free foam cased in a steel shell and has an ozone depletion potential
(ODP) of zero and a global warming potential (GWP) of 1.
The specification of the models are shown in the following tables.
DESIGN
TECHNICAL DATA
Stainless Lite Direct Buffer Store Technical Specification
Description
90D
120D
210D
300D
400D
Capacity
litres
90
120
210
300
400
Height
mm
745
930
1495
1992
2030
Diameter
mm
550
550
550
550
630
Weight (empty)
kg
13
18
28
37
51
Weight (full)
kg
103
138
238
337
451
Standing losses
kWhr/24hr
0.85
1.06
1.70
2.04
2.82
Maximum working pressure - cylinder
bar
3.5
3.5
3.5
3.5
3.5
Maximum working pressure - space heating
bar
3.5
3.5
3.5
3.5
3.5
Central heating flow connection
mm
28
28
28
35
35
Central heating return connection
mm
28
28
28
35
35
Heat pump flow connection
mm
28
28
28
35
35
Heat pump return connection
mm
28
28
28
35
35
Central heating flow tapping height
mm
732
920
1483
2020
2030
Central heating return tapping height
mm
200
200
200
200
214
Heat pump flow tapping height
mm
690
690
1253
1791
1805
Heat pump return tapping height
mm
300
300
300
300
314
Thermostatic pocket size - Bottom
mm
22
22
22
22
22
Thermostatic pocket size - Top
mm
22
22
22
22
22
Thermostatic pocket height - Bottom
mm
245
257
446
607
621
Thermostatic pocket height - Top
mm
448
571
937
1287
1201
Heating Flow
Heat Pump Return
Heating Return
Heat Pump Flow
Sensor Pocket
Sensor Pocket