Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
1
BLC s
peCifiCations
BLC-1/3-2
s
tanDaRD
f
eatuRes
:
• Glycol connections with flared fittings for easy service access
• Durable black vinyl-clad exterior with 16 gauge galvanized steel base
• Stainless steel, CFC-free, foamed-in-place insulated glycol bath
• High efficiency heat exchanger minimizes glycol bath size to one gallon
• Front located glycol filling port
s
tanDaRD
f
eatuRes
:
• Control panel is removable and includes wall bracket for remote installation
• Glycol connections with flared fittings for easy service access
• Durable black vinyl-clad exterior with 16 gauge galvanized steel base
• Stainless steel, CFC-free, foamed-in-place insulated glycol bath
• High efficiency heat exchanger minimizes glycol bath size to one gallon
• Front located glycol filling port
• Digital temperature control with LCD display
• Over-sized condenser coil for maximum efficiency
• Clear glycol bath cover for easy visual inspection
• Available with two recirculating pumps (designated by “-2” suffix in model number)
Dimensional and Specification Information
1/3 HP Beer Line Chiller
Model: BLC-1/3-E
1/3, 1/2, and 3/4 HP Beer Line Chillers with Remote Installable Control Panel
Models: BLC-1/3, BLC-1/3-2, BLC-1/2, BLC-1/2-2, BLC-3/4, BLC-3/4-2
Model No.
BLC-1/3-E
BLC-1/3
BLC-1/3-2
BLC-1/2
BLC-1/2-2
BLC-3/4
BLC-3/4-2
Dimensions
†
Length
27"
27"
27"
27"
27"
27"
27"
Width
21-1/4"
25-5/8"
25-5/8"
25-5/8"
25-5/8"
25-5/8"
25-5/8"
Height
14-3/4"
16"
16"
16"
16"
16"
16"
†
Note: A minimum six inch clearance should be allowed around the entire unit for proper air flow.
Additional clearance should be considered above and in front of the unit for service access.
Electrical
Voltage
120V
120V
120V
120V
120V
230V
230V
Frequency
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
Phase
1ø
1ø
1ø
1ø
1ø
1ø
1ø
FLA
12.5
12.5
17.5
13.6
18.6
10.1
12.9
Dedicated
Circuit
20A
20A
30A
20A
30A
20A
20A
Electrical
Connection
Cord & Plug Cord & Plug
Hard Wire
Cord & Plug
Hard Wire
Cord & Plug Cord & Plug
Refrigerant
R134a
R134a
R134a
R134a
R134a
R134A
R134A
Compressor
1/3 HP
1/3 HP
1/3 HP
1/2 HP
1/2 HP
3/4 HP
3/4 HP
Max Distance to Taps
125 ft.
125 ft.
125 ft.
250 ft.
250 ft.
400 ft.
400 ft.
Circulating Pumps
60 gph
60 gph
60 gph
60 gph
60 gph
60 gph
60 gph
Glycol Bath Capacity
.94 gal
.94 gal
.94 gal
.94 gal
.94 gal
.94 gal
.94 gal.
Shipping Weight LBS (kg)
128 (58.1)
150 (68.0)
163 (73.9)
153 (69.4)
166 (75.3)
175 (79.5)
193 (87.7)