background image

Glastender, Inc.  •  5400 North Michigan Road  •  Saginaw, MI  •  48604-9780  

800.748.0423  •  989.752.4275  •  Fax 989.752.4444  •  www.glastender.com

15

p

RiCes

:

All prices are LIST. Applicable taxes will be added.

Q

uotations

:

Unless otherwise stated, quotations are effective for 30 days only.

a

CCeptanCe

:

All orders are subject to acceptance by Glastender, Inc.’s headquarters 

in Saginaw, Michigan. Possession of the Parts Directory and Price List 

is not an offer to sell.

s

hipments

:

F.O.B.  factory  in  Saginaw,  Michigan.  Partial  shipments  will  be  made 

unless otherwise specified by the customer. Orders are shipped via UPS 

or DHL unless otherwise specified.

p

ayment

 t

eRms

:

Cash should be included with all orders unless credit terms have been 

arranged. To establish credit, banking and trade references are required. 

A  convenient  credit  application  is  available  upon  request.  Visa  and 

Mastercard are also accepted.

D

eLiveRy

:

Varies  according  to  prior  production  commitments,  but  parts  orders 

generally ship within two working days.

R

etuRns

:

A Return Authorization (RA) number must be issued by the factory in 

advance for any items that are returnable. The RA number MUST be 

noted on the outside of the returned package. Returns must be received 

within 90 days of the RA issue date. Shipping charges must be prepaid. 

A  20%  handling  charge  will  be  applied  to  all  authorized  returns  if 

received in new, unused condition in the original packaging.

L

oss

 

oR

 D

amaGe

:

Glastender,  Inc.  is  not  responsible  for  any  loss,  damage,  or  delay  of 

merchandise  during  shipment.  Such  transit  claims  must  be  filed  with 

the  carrier.  Merchandise  must  be  examined  on  arrival.  If  shortages 

occur, Glastender, Inc. must be notified in writing within five (5) days 

of delivery to honor any shortage claim.

NOTE: Glastender, Inc.’s policy of constant quality improvement means 

that  prices,  specifications,  and  policies  are  subject  to  change  without 

notice.

IMPORTANT!!

Attention Refrigeration Service Companies

Please review the important warranty information on this page. If you believe a

service call should be covered by the factory, please call the factory for authorization

between 8AM and 5PM EST, Monday through Friday.

t

eRms

 

anD

 C

onDitions

W

aRRanty

 s

tatement

LABOR: Glastender, Inc. warrants all products to be free of defects in 

material  and  workmanship.  In  established  areas,  a  start-up  and  a  90-

day  labor  warranty  are  included  with  glasswasher  models  GT-24  and 

GT-30. The GT-18 series glasswashers include a 90-day labor warranty. 

Self-contained refrigeration models, except beer line chillers, include a 

1-year labor warranty, for the duration of one year from date of instal-

lation  or  up  to  18  months  from  date  of  factory  shipment,  whichever 

occurs sooner. For warranty labor claims beyond 15 months from the 

date of factory shipment, proof of date of installation or occupancy must 

be provided. Authorization for labor must be obtained from Glastender 

within  the  warranty  period  and  prior  to  the  service  being  performed. 

Labor warranty applies to the United States and Canada only.

PARTS: Within one year from date of installation, or 15 months from 

date  of  factory  shipment,  whichever  occurs  sooner,  Glastender,  Inc. 

will replace any part or assembly found defective under normal use and 

service. Field replacement parts include a warranty of 90 days from date 

of installation. All self-contained refrigeration models include a 5-year 

compressor warranty. 

A warranty claim form MUST accompany all returned defective parts or 

assemblies. This form MUST be completed in full. Failure to do so may 

result in delay or denial of credit. Any defective part or assembly must 

be returned to Glastender, Inc., Saginaw, Michigan, with all transporta-

tion and delivery charges prepaid. Warranty repairs or replacements will 

be shipped FOB factory in Saginaw, Michigan.

The warranty does not cover equipment subjected to accidents, freight 

damage, alterations, improper power and/or plumbing hookups, improp-

er chemical use, general misuse, or lack of routine required maintenance 

as determined by Glastender, Inc. 

No representative, distributor, dealer, or any other person is authorized 

to  modify  this  warranty.  This  warranty  replaces  all  other  written  or 

verbal warranties.

NOTE:  Glastender,  Inc.’s  policy  of  constant  quality  improvement 

means  that  prices,  specifications,  and  policies  are  subject  to  change 

without notice. Questions regarding this warranty should be directed to 

Glastender’s Customer Service Representative.

03/01/07

Summary of Contents for BLC-1/2

Page 1: ...rth Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com BLC 1 3 E BLC 1 3 BLC 1 3 2 BLC 1 2 BLC 1 2 2 BLC 3 4 BLC 3 4 2 Remote Draft Beer Line Chillers 2008 Glastender Inc Rev 08 26 08 BLC 1 3 E BLC 1 3 2 BLC 3 4 2 ...

Page 2: ......

Page 3: ...p 3 Electronic Temperature Control Programming 4 Cold Control Adjustment 4 Wiring Diagrams 4 5 BLC 1 3 E 4 BLC 1 3 BLC 1 3 2 BLC 1 2 BLC 1 2 2 5 BLC 3 4 BLC 3 4 2 5 Typical Installation Detail 6 Remote Control Panel Installation Detail 7 Remote Installation Directions 8 Remote Control Panel Installation Photo 9 Remote Beer Line Chiller Accessories 9 Replacement Parts 10 13 BLC 1 3 E 10 BLC 1 3 BLC...

Page 4: ...ecification Information 1 3 HP Beer Line Chiller Model BLC 1 3 E 1 3 1 2 and 3 4 HP Beer Line Chillers with Remote Installable Control Panel Models BLC 1 3 BLC 1 3 2 BLC 1 2 BLC 1 2 2 BLC 3 4 BLC 3 4 2 Model No BLC 1 3 E BLC 1 3 BLC 1 3 2 BLC 1 2 BLC 1 2 2 BLC 3 4 BLC 3 4 2 Dimensions Length 27 27 27 27 27 27 27 Width 21 1 4 25 5 8 25 5 8 25 5 8 25 5 8 25 5 8 25 5 8 Height 14 3 4 16 16 16 16 16 16...

Page 5: ...TE A minimum of six inches of clearance should be allowed around the entire unit for proper perfor mance Additional clearance should be considered for above the unit and in front of the unit for ser viceability If the unit is located on the floor Ensure the cabinet is sealed to the floor with NSF listed silicon RTV sealant applied around the entire bottom edge of the cabinet An optional 4 leg set ...

Page 6: ...he top 6 Unit Start Up Connect unit to appropriate electrical circuit For more information refer to Step 3 Electrical Hook Up Model BLC 1 3 E has one power switch that operates the compressor unit and recirculating pump Models BLC 1 3 BLC 1 3 2 BLC 1 2 BLC 1 2 2 BLC 3 4 and BLC 3 4 2 have a condensing unit power switch There are separate power switches to operate the recirculating pumps The conden...

Page 7: ...setpoint Step 3 Press the SET key again to access the differential To achieve the desired differential press the UP key to increase or the DOWN key to decrease the setting Step 4 Press the SET key again to access the mode Use the up or down arrow to toggle between and select C1 cooling or H1 heating mode Step 5 Press the SET key again to complete programming Cold Control Adjustment BLC 1 3 E The u...

Page 8: ...GREEN BLACK PUMP SWITCH 1 RED BLACK GREEN RECIRC PUMP M RED RED OPTIONAL 12ga 12ga COM NO NC C HIGH PRESSURE SWITCH PUMP SWITCH 2 120V 230V BLACK COMPRESSOR SWITCH OPEN 250 PSIG BLUE RED CONVERT COLOR TO RED BLC 1 3 BLC 1 3 2 BLC 1 2 BLC 1 2 2 Wiring Diagram Single Pump Full Load Amps 12 5 1 3hp Electrical Service Required 20amp Dual Pump Full Load Amps 18 6 1 3hp Electrical Service Required 30amp...

Page 9: ...Glastender Inc 5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com Typical Installation Detail ...

Page 10: ...Glastender Inc 5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com Remote Control Panel Installation Detail ...

Page 11: ...l and insulate glycol line from heat exchanger to bath Disconnect glycol line from heat exchanger Remove cabinet top and vented side to get at the power cord Disconnect 33 power cord Install power line between condensing unit and control panel Remove control panel installed with four screws from cabi net NOTE Wall rack will be found behind control panel Disconnect glycol line from bath Remove cont...

Page 12: ... models Wall Racks Leg Sets Stands Remote Beer Line Chiller Accessories The Glastender exclusive patent pending beer line chiller design houses the heat exchanger inside the condensing unit compartment This unique feature allows the control panel with glycol bath and recir culating pump s to be easily installed separately from the condensing unit in a more conveniently accessible location Simply r...

Page 13: ...lade 40 series 13 00 5 06001385 Filter dryer 1 4 x 1 4 15 00 6 06001384 Accumulator suction line 32 00 7 09000523 Evaporator flat plate housing assembly 515 00 8 09000331 Pump glycol 60 GPH brass 190 00 9 09000340 Pump motor 1 3HP 115v 300 00 10 06001595 Insulation Fluid O Tech pump 2 piece set 9 00 11 06001412 Rocker switch 5 00 12 09000303 Thermostat adjustable 100 00 13 09000527 Capillary tubin...

Page 14: ...r Inc 5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com 11 16 15 14 BLC 1 3 BLC 1 3 2 BLC 1 2 BLC 1 2 2 Replacement Parts 2 8 7 9 11 10 12 3 5 4 1 6 13 ...

Page 15: ...de 10 30 degree S Condenser 14 00 5 06001385 Filter dryer 1 4 x 1 4 15 00 6 06001384 Accumulator suction line 32 00 7 09000523 Evaporator flat plate housing assembly 515 00 8 09000331 Pump glycol 60 GPH brass 190 00 9 09000340 Pump motor 1 3 HP 115V 300 00 10 06001595 Insulation Fluid O Tech pump 2 piece set 9 00 11 06001412 Rocker switch 5 00 12 09000616 Electronic temperature control 185 00 13 0...

Page 16: ...Glastender Inc 5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 989 752 4444 www glastender com 13 BLC 3 4 BLC 3 4 2 Replacement Parts 7 8 2 3 5 4 1 6 13 14 15 16 12 9 10 11 ...

Page 17: ...ator 100 00 7 09000523 Evaporator flat plate housing assembly 500 00 8 09000331 Pump glycol 60 GPH brass 190 00 9 09000342 Pump motor 1 3hp 220v 315 00 10 06001595 Insulation Fluid O Tech Pump 2 piece set 9 00 11 06001412 Rocker Switch 5 00 12 09000616 Electronic Temperature Control 185 00 13 09000649 Capillary tubing set of 2 60 x 049 ID 20 00 14 09000496 Top compressor black vinyl flat plate chi...

Page 18: ...M EST Monday through Friday Terms and Conditions Warranty Statement LABOR Glastender Inc warrants all products to be free of defects in material and workmanship In established areas a start up and a 90 day labor warranty are included with glasswasher models GT 24 and GT 30 The GT 18 series glasswashers include a 90 day labor warranty Self contained refrigeration models except beer line chillers in...

Page 19: ...________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________...

Page 20: ...ted design flexibility Each piece of equipment is engineered with features that enhance your efficiency ease your maintenance and prolong the life of your investment The flexibility you want The features you need Glastender Expect more U N P A R A L L E L E D U N D E R B A R D E S I G N E N G I N E E R I N G GLASSWASHERS COCKTAIL STATIONS COOLERS FROSTERS BEER SYSTEMS ...

Reviews: