background image

8

Vertical LED Task Lights for Recessed Mounted 

4” Deep or 6” Deep Mirrored Cabinet

FOR INSTALLATION OF A RECESSED MOUNTED CAB-
INET BE SURE TO TURN OFF THE POWER AT THE
SERVICE PANEL BEFORE WORKING ON WIRING.

1. Adding the Vertical LED Task Lights to any cabinet in-
creases the width of the framed Rough Opening by 4 3/4”
(2 3/8” for each fixture on the left and right). Frame
according to the Cabinet Manual with this additional 
dimension. (See page 5 for the modified Rough Opening 
Dimensions.)

2. Install the rough service wiring from the switch as 
located in the wall near the final cabinet position. Rough
wire from the Switch Box to the general area for each light
at the measured and marked location for the cabinet instal-
lation. Drill the wire access hole (1 1/2” dia) to align with
the selected access hole in the fixture.

Assemble the Cabinet with the Light Fixtures:

3. To install the light fixture on the cabinet and to connect
the power supply you must gain access to the interior of
the light fixture. Open the fixture with these steps: 
-- Remove Top & Bottom plates with the two screws 

located in the rectangular
part of the plates. 
-- Remove the acrylic 
diffuser by squeezing from
the narrow side and 
pivoting it away from the
fixture. 
-- Unscrew the three 
flathead stainless screws holding the
outer Mounting LED Panel, the panel
with the mounted LED strips . Pivot the
outer Mounting Panel to the outside
and 
disconnect the plug that connects the
12V LED Driver box to the light strips
and set the LED Mounting Panel 
assembly aside. 

4.  Holding the inner wall panel of the fixture against the outer wall of
the cabinet align the two factory installed connecting brackets with the
proper holes in the cabinet wall and attach this part of the light fixture
with the four (4) #10-32 screws supplied. (Reminder: the 30” and 36”
Vertical lights come marked as left and right. Keep the parts for each
light fixture separate until reassembly.

Repeat these steps for the opposite light fixture.

BLACK

WHITE

12V LED DRIVER

GREEN

L

G

N

TERMINAL 

BLOCK 

SERVICE WIRE

Detail #1

SECTION VIEW OF A 4” RECESSED CABINET WITH VERTICAL LED TASK LIGHTS.

Squeeze
Diffuser and
Pivot away
from 
Narrow side

Remove top 
and 
bottom Plates

NOTE: TAKE CARE IN HANDLING AND 
INSTALLING TO AVOID DAMAGE TO MIRRORS.
ALWAYS PLACE THE MIRRORED CABINET ON A
PADDED SURFACE TO PROTECT GLASS.

Summary of Contents for GC1624

Page 1: ...e following instruction sheets are applicable for installation of this accessory on all Flat or Beveled Frameless Mirror Cabinets both 4 deep and 6 deep This accessory also may be added to any previou...

Page 2: ...of electric shock 1 Turn Power off at service panel before working on wiring 2 DO NOT SPRAY LIQUID CLEANERS on the Vertical LED Task Light For cleaning we recommend using ammonia free Sprayway brand...

Page 3: ...Installation Wood Screw 4 10 31 Screws 8 Left Not to Scale Each pair of lights ships with one parts package Right Not to Scale Includes Wire Bushing Top Bottom Plate Cover Screw Guide Installation Par...

Page 4: ...led wiring or any of its features or appurte nances 4 This unit s service wiring and electrical connections must be made by a Licensed Electrician in a manner that conforms to the National Electric Co...

Page 5: ...ire for pull through RECESSED MOUNT Important Make sure you allow for a minimum of 1 clearance above any obstruction such as faucets etc Avoid installing light fixtures too close to sinks RECESSED MOU...

Page 6: ...om plates with the two screws located in the rectangular part of the plates Remove the acrylic diffuser by squeezing from the narrow side and pivoting it away from the fixture Unscrew the three flathe...

Page 7: ...2 Side Mirror Brackets on the outside face of the Mounting Panel using the screws and Brackets in the Side Mirror Kit See page 11 for details Do not remove the paper covering the adhesive until you a...

Page 8: ...h the two screws located in the rectangular part of the plates Remove the acrylic diffuser by squeezing from the narrow side and pivoting it away from the fixture Unscrew the three flathead stainless...

Page 9: ...Move the wire bushing to the wire entry holes you plan to use Insert the service wire through the wire bushing at the selected locations and pull the service wire through c Trim the wire cable leavin...

Page 10: ...pending the Electrician s wiring plan this allows a through wire connection for the secparate 20A GFCI circuit for the E O cabinet to go through a Light Fixture and into the shelf The Service to the C...

Page 11: ...of the side mirror kit panel with the Alcohol pads Check alignment before you attach the mirror to be sure it will align even with the top of the cabinet 8 Peel off paper covering of the adhesive tap...

Page 12: ...f the mirror surfaces Carefully remove the door from the carton Hold the door in the upright position snap open the factory installed hinges Place the hinge onto the factory installed mounting toe hin...

Page 13: ...lace Step 2 Test Door Clearance Door Installation continued CAUTION Always test by closing the door with your hand behing the door to test door clearance and determine if any adjustment is needed to a...

Page 14: ...e as shown Left and right hinge adjustment is limited to 1 32 1 mm Test by closing the door with your hand behing the door to test the clearance to avoid door hitting Top and Bottom Light Cover Plates...

Page 15: ...w This will eliminate the possibility of the door hitting a wall sconce or other decorative items Special adjustments of these clips is required with the Vertical Light Mirrored Cabinet Use caution wh...

Page 16: ...installation or if the reported defects are a result of faulty installation abuse misuse abnormal wear poor maintenance accident or repairs by service personnel other than the original professional in...

Reviews: