EnSet
©
Plus / Original / Compact
Version 03 - 15.10.2018
22/40
5.2.2
EnSet
©
Plus Pressure Mode
No.
Description
In this mode you set the air pressure for the input and the foot pedal controls
the number of impacts per minute (speed) of the tool.
(A)
Press « Mode » button
(12)
to select the EnSet
©
Plus mode
.
By pressing on the « Mode » button
(12)
you can toggle back and forth
between Original and Plus modes.
In the pressure mode the air pressure is displayed in the top « Pressure »
window. The bottom window displays « 0 » (zero) until you engage the foot
pedal. Once you step on the foot pedal you will see a variable number of
pulses in the bottom window.
(B)
Use the « + » and « - » buttons
(9)
to the right of the top pressure window to
adjust the working air pressure up or down between 35 - 100 psi (2.41 -
7 bar).
In this mode the number of impacts per minute will be displayed in the bottom
window as you step on the foot pedal. The harder you step on the foot pedal
the more impacts will occur (faster speed). The display
(13)
in the bottom
window will continually adjust based on how much pressure is being applied
to the foot pedal.
The number of impacts displayed in the bottom « Pulse » window
(13)
must be
multiplied by 60 to get the actual number of impacts/minute. For example :
1 * 60 = 60 impacts/minute
4 * 60 = 240 impacts/minute
10 * 60 = 600 impacts/minute
Maximum number of impacts/minute is 2 400 (40 * 60)
Summary of Contents for EnSet Compact
Page 1: ...User Manual EnSet Plus EnSet Original EnSet Compact ...
Page 17: ...EnSet Plus Original Compact Version 03 15 10 2018 17 40 ...
Page 23: ...EnSet Plus Original Compact Version 03 15 10 2018 23 40 EnSet Plus ...
Page 29: ...EnSet Plus Original Compact Version 03 15 10 2018 29 40 ...
Page 31: ...EnSet Plus Original Compact Version 03 15 10 2018 31 40 ...
Page 37: ...EnSet Plus Original Compact Version 03 15 10 2018 37 40 ...
Page 39: ...EnSet Plus Original Compact Version 03 15 10 2018 39 40 Notes ...