Glacial 8LDIECH-SC-WFC-SSF User Manual Download Page 3

 

 

   

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, 

fire, or electrical shock.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected water cooler: 

This water cooler  must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of 

electrical shock by providing a path of least resistance for electric current. This water cooler is equipped with a cord having 

an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is 

properly installed and grounded in accordance with all local codes and ordinances.

                                                Improper connection of the equipment-grounding conductor can result in a risk of electric 

                                                shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the 

appliance is properly grounded. 

Do not modify the plug provided with the appliance-if it will not fit the outlet, have a proper outlet installed by a 

qualified electrician.

A 120 volt, 60 Hz., AC only, 15 amp, fused electrical supply is required. A time-delay

fuse or circuit breaker is recommended. Do not overload the ciruit, provide separate circuit,  

if required, to serve only this appliance.

This water  cooler is equipped with a power supply cord having a 3 prong grounding plug.

To minimize possible shock hazard, the cord must be  plugged into a mating, 3 prong, 

grounding-type outlet, grounded in accordance with local codes and ordinances,a mating 

outlet is not available, it is the personal responsibility and obligation of the customer to have 

the  properly grounded outlet installed by a qualified electrician.

If codes permit and a separate ground wire is used, it is recommended that a qualified 

electrician determine that the ground path is adequate.

Do not ground to a gas pipe.

Check with a qualified electrician if you are not sure the water cooler is properly grounded.

Do not have a fuse in the neutral or ground circuit.

“Please make sure that ELECTRICAL  OUTLET IS PROPERLY WIRED   

TO CORRECT SIZED   CIRCUIT BREAKER OR FUSE AND PROPERLY 

GROUNDED.  MUST BE WIRED TO  HAVE CORRECT POLARITY.

WARNING 

!

WARNING 

!

SAFETY PRECAUTIONS --Electrical Requirements

 

IMPORTANT: Do NOT Return Dispenser To Store. 

If you have a question or problem, please contact 888-828-1426 for assistance. 

3

Summary of Contents for 8LDIECH-SC-WFC-SSF

Page 1: ... Hot Cold Hidden Bottle Water Cooler with Display Model 8LDIECH SC WFC SSF TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE USER MUST READ THIS MANUAL BEFORE ASSEMBLING INSTALLING OPERATING DISPENSER SAVE THIS MANUAL FOR FUTURE USE USER MANUAL 8LDIECH SC WFC SSF 2012 Electrotemp Technologies Inc PN 5M009433X1 ...

Page 2: ...stall and use only on a hard flat and level surface Do NOT place dispenser into an enclosed space or cabinet Do NOT operate dispenser in the presence of explosive fumes Position back of dispenser no closer than 4 inches from wall and permit free airflow between wall and dispenser There must be at least 4 inches clearance on the sides of the dispenser to permit airflow Use only properly grounded ou...

Page 3: ...0 volt 60 Hz AC only 15 amp fused electrical supply is required A time delay fuse or circuit breaker is recommended Do not overload the ciruit provide separate circuit if required to serve only this appliance This water cooler is equipped with a power supply cord having a 3 prong grounding plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong grounding type outlet g...

Page 4: ...urchased Staple your receipt to manual You will need this information to obtain warranty service Product Self Cleaning Hot Cold Hidden Bottle Water Cooler With Display Model Number 8LDIECH SC WFC SSF Serial ID Number Date of Purchase Safety Precautions 2 Safety Precautions Electrical Requirements 3 Key Information for Future Use 4 Specifications 5 Parts Features 5 Assembly 6 Cleaning Prior to Init...

Page 5: ...ATURES 37 5 Ibs 17Kg 1 2 1 2 3 3 4 5 4 5 6 6 7 7 8 8 9 9 10 11 10 11 12 12 13 13 14 3 14 3 21 3 15 15 16 17 16 17 18 18 19 19 21 20 20 Control Hot Water Hot Water Release Control Cold Water Tap Hot Water Tap Cold Water LED Night light Drip Tray Door Bottle Tray Cold Power Switch Energy Saving Hot Power Switch Energy Saving Carry Handle Cooling Thermostat Drain Plug Bottle Probe Door Switch Water P...

Page 6: ...F 3 Unplug power cord from wall outlet 4 Remove water bottle and probe from water bottle 5 Place a 2 gallon or larger bucket under the probe assembly Dis assembly probe assembly wash probe parts by hand in soapy water or in the dishwater 6 Romove air filter and wash in soapy water 7 8 Submerge probe hand in the soapy water and rinse properly 9 Assemble back all parts of probe assembly 10 spay disp...

Page 7: ...3 minutes or until the pump stops 15 Complete the installation and operation instructions within this manual If your water has an off taste Do not return to store Call 888 828 1426 for assistance INSTALLATION 1 Place dispenser upright 2 Locate dispenser on a hard and level surface in a cool shaded location near a grounded wall outlet Notice Do NOT plug in power cord yet 3 Position dispenser so the...

Page 8: ... bottle with a soft cloth and warm soapy water then rinse Remove entire plastic cap from top of bottle Insert probe into bottle Push down on probe until it is seated 2 This model uses an pump to force water from the bottle to the reservoirs Please do the following i Clean bottle cap and neck ii Remove entire plastic cap from bottle iii Adjust length of probe by pulling B portion of tube to its max...

Page 9: ...s switch OFF Notice For unit to operate properly the probe head must be seated on the bottle and the door must be fully closed It will take up to 3 minutes for the reservoirs to load During this time the pump will run on and off This is normal Each time you dispense water from the taps the pump will come on to refill the tanks This is normal Water will be pumped into the hot and cold water reservo...

Page 10: ...rd to start flow 3 Release control once desired fill level is achieved Dispense Hot Water This unit dispenses water at temperatures that can cause severe burns Avoid direct contact with hot water Keep children and pets away from unit while dispensing Never allow children to dispense hot water without proper and direct supervision Note After setup hot water will be available in 15 20 minutes 1 Posi...

Page 11: ...ere may be a small amount of water left in the bottle This is normal if you need assistance please contact customer service 1 Open door and slide bottle out 2 Remove probe from bottle Pull probe straight up until completely out of bottle 3 Install fresh bottle Place fresh bottle in front of tray Clean fresh bottle with a soft cloth and warm soapy water then rinse Remove entire plastic cap from top...

Page 12: ...oading a fresh bottle Step A Remove Existing Water 1 Move dispenser away from wall and turn it 90 in either direction 2 Turn energy saving switches to OFF 3 Unplug power cord from wall outlet 4 Remove water bottle and probe from water bottle 5 Place a 2 gallon or larger bucket under the drain plug in the rear of the dispenser 6 Remove drain cap and silicon plug Cold water will immediately flow int...

Page 13: ...p of the water bleach solution through each tap to clean out the water ways 10 Place a 2 gallon or larger bucket under the drain plug in the rear of the dispenser 11 Remove drain cap and silicon plug Cold water will immediately flow into the bucket Several seconds later hot water will dispense Reminder Place drain cap and silicon plug in a safe location so they are not lost 12 Once unit has draine...

Page 14: ...words SELF CLEANING Display time setting 15 How to switch Off Beeping signal Bottle icon on the display will flash and beep when bottle is empty To turn beeper off touch for 3 seconds words on the panel marked BEEP ON OFF Beep ON or OFF markings are shown here Display s Operation explanation SET the clock System just electricity the clock default from 12 00 PM start the timer Hold SET key for 3 se...

Page 15: ...will show 15 bottles after you place first bottle into your dispenser It will show one less each time you change the bottle To make counter run properly you must change bottle only after EMPTY Bottle alarm is shown on the display Flashing picture of the water bottle Your display will show 0 bottles either after you had used 15 bottles of water or after the expiry of 3 month s time FILTER CHANGE wi...

Page 16: ...ides of the dispenser Make sure energy saving switch is ON Adjust thermostat by turning clockwise Adjust in a single increment of 30 degrees of a circle the equivalent of 1 hour on a standard analog clock face Wait 1 hour for results If unsatisfactory adjust another 30 degrees clockwise wait then asses results Thermostat is located at back of unit Hot water is not hot It takes 15 20 minutes after ...

Page 17: ...y you or any third party or failure to perform normal and routine maintenance on the dispenser as set out in the User s Manual In addition the Limited Warranty does not cover damages to the finish such as scratches dents discoloration or rust after purchase The Limited Warranty is in lieu of all other express warranties Vendor disclaims all warranties for products that are purchased from seller ot...

Page 18: ...名称 网销说明书8LDIECH SC WFC SSF GLACIAL English 图号 5M009433X1 技术要求 1 尺寸 143 210mm 2 单色印刷 3 产品符合Rosh要求 4 批量生产前一定要样品确认 不得擅自更改图纸 设计 审核 批准 ...

Reviews: