28
GKD Technik Ltd
M3000007
RF Tandem Li�
Connect the RF Tandem Modems, one to each display via the Female M12 connector, on the back of each
display. Posi�on the RF Tandem Modems inside the Cab, so that they do not obstruct the movement of the
machine.
On the Operator Screen, press on the Menu bu�on.
From the Restric�ons Tab, press on the Tandem Bu�on.
On the window that appears (shown here) press Yes.
Return to the Operator Screen.
Repeat this process on the second machine that has the RF
Modem fi�ed.
Once the system have paired, the Operator
Screen will change to show the following:
The current Load On Hook of the Paired Machine.
The Safe Working Load bar graph (right hand side)
will now show machines 1 and 2.
Tandem
will be shown at the bo�om of the screen.
Machines current Load on Hook
Paired machines current Load on Hook
Once the 2 machines are connected, the Tandem Li� Opera�on can now be carried out.
During opera�on, if either one of the machines reaches its Max Safe Working Load, i.e. Overload, then both
machines will be mo�on cut. There are 2 messages that can be shown.
Paired Machine in Mo�on Cut
This will be shown if the machine you are in reaches its
Max Safe Working Load.
When this happens, all mo�ons on both machines are
cut and a similar message is shown to the other
Operator.
Pressing Release will allow you to lower the load, and
therefore move the machine out of Overload, while
the mo�on will remain cut in an upward direc�on, to
prevent the Overload condi�on from being increased.