gk-medizinmechanik GK Magic 1000 User Manual Download Page 14

13 

Functions 

 

Are  there  any  persons  which  may  not  be  exposed  to  the  ultrasound 
cleaning function? 

 
In  general  (with  the  exception  of  pregnant  women)  the 
ultrasound  cleaning  function  may  be  used  on  all  per-
sons  which  are  also  allowed  to  take  a  bath.  In  case 
you are not sure, ask a medical doctor if the applica-
tion  of  the  ultrasound  cleaning  (at  25  to  30  KHz  and 
about  100  mW/cm²)  is  safe  for  the  patient’s  health 
condition. (Also see the following questions.) 
 

May the ultrasound cleaning function be used on pregnant women? 

 
For safety's sake pregnant women may not be exposed to 
the  ultrasound  cleaning  function.  (Should  it  still 
happen unintentionally, then there normally is no harm 
to be expected, since the intensity used is low at 100 
mW/cm².  Still,  one  should  not  take  unnecessary  risks 
regarding the life of others.) 
 

May  the  ultrasound  cleaning  function  be  applied  to  people  with 
pacemakers? 

 
We have no information about any disruption of a pace-
maker’s  functionality  because  of  ultrasound  or  an  ul­
trasound transducer. 
 

May  the  ultrasound  cleaning  function  be  applied  to  persons  with 
implants or other metal objects in or on their body? 

 
Implants or other metal objects are no problem. 
 

For how long at a time may the ultrasound cleaning function be ap-
plied to a person? 

 
The  ultrasound  used  would  not  have  any  negative  ef-
fects  for  the  body,  regardless  of  the  duration  of  ex-
posure  to  it.  Still,  for  the  sake  of  usefulness  and 
practicality  the  ultrasound  cleaning  function  has  a 
build-in time limit. 
 

Should  any  bath  additives  be  used  during  the  application  of  the 
ultrasound cleaning? 

 
Bathing  oils  should  be  avoided,  since  these  have  a 
negative impact on the effectiveness of the ultrasound 
cleaning. However, shampoo may be used. 

Summary of Contents for GK Magic 1000

Page 1: ......

Page 2: ...and translation of both the whole document as well as of any parts thereof Congratulations on your decision to purchase a GK Bathtub You have acquired an Austrian quality prod uct which will considera...

Page 3: ...er 8 Setting the temperature 9 Temperature display tub fill shower 9 Underwater light 9 Sound Vision 10 Ultrasound 11 Ultrasound cleaning FAQ 11 13 Hydromassage 14 Shampoo Bath additive 14 Disinfectio...

Page 4: ...ce etc Never leave the patient unattended inside the bathtub Ensure that the equipment is thoroughly cleaned after every use When using disinfection protect your skin and eyes Heed all instructions on...

Page 5: ...4 3 2 1 8 11 10 5 6 7 Components Components 1 Disinfection 2 Lid 3 Shower 4 Control panel 5 Mixer 6 Shampoo Bath additive dispenser 7 Fill in spout 8 Overflow 9 Hydromassage jets 10 Drain 11 Grab han...

Page 6: ...5 Components Hydromassage jet Box for care and disinfection liquids USB port Flowmeter with con centration table...

Page 7: ...Sensor Activation card 6 Button Down 7 Button Up 8 Button Tub fill 9 Button Shower 10 Button Bath additive 11 Button Disinfection 12 Button Shampoo 13 Button Hydromassage Ultrasound 14 Button Underwa...

Page 8: ...oment and locked Only the sensor ACTIVATION CARD is illuminated with a green backlight The standby mode a prevents unauthorized use of the bathtub and b helps to save energy since due to the deactivat...

Page 9: ...n TUB FILL the tub starts filling The button starts flashing and the symbol TUB FILL TEMPERATURE lights up The water now flows into the bathtub until the maximum filling level has been reached or the...

Page 10: ...MPERATURE is illuminated additionally to the flashing button TUB FILL If the shower is active the symbol SHOWER TEMPERATURE is illuminated additionally to the flash ing button SHOWER If tub fill and t...

Page 11: ...on PLAY PAUSE during playback it is paused and the button starts to shine continu ously When pressing it again the playback contin ues In case the pause exceeds 30 seconds the player resets itself to...

Page 12: ...ination of the button stops and it can not be used until the next bathing cycle Note The ultrasound transducer is audible The closer any body parts are to the transducer plate the louder the side nois...

Page 13: ...and spread out through the bathing water What effect does ultrasound have regarding body cleaning Because of the ultrasound millions of tiny gas bubbles are created in the water which collapse again v...

Page 14: ...take unnecessary risks regarding the life of others May the ultrasound cleaning function be applied to people with pacemakers We have no information about any disruption of a pace maker s functionalit...

Page 15: ...massage hose coupling is installed then also the jet containing the coupling will be activated immediately without delay upon activation of the whole function Shampoo Bath additive Both of these prod...

Page 16: ...s infection button is flashing fast 4x sec To start the disinfection procedure take the red hand shower from its holder and press the disinfection but ton The button is flashing now Spray all internal...

Page 17: ...Always check the water temperature with your bare hand also when using the shower before bringing the water in contact with the patient To add bath additive to the water if installed available press t...

Page 18: ...y damage caused by unapproved unsuitable products will not be covered by the manufacturer s warranty Dark grey and transparent plastic parts The dark grey and transparent plastic parts may only be cle...

Page 19: ...h From time to time the hydromassage jet covers should be removed and be cleaned together with the inlet and outlet aper tures separately To do so unscrew the jet covers in counter clockwise direction...

Page 20: ...infection doesn t work and the button is flashing very fast about 4x sec even though the container is full The disinfection sensor is defective and has to be replaced All the functions are disabled ex...

Page 21: ...or other dam ages Caution Should you notice any damage to the bathtub either during maintenance or at any other time then the bathtub may not be used any further from that point onward until the damag...

Page 22: ...0 C Max relative humidity 80 not condensed at 20 C Atmospheric pressure range 500 hPa to 1060 hPa Transport and Storage Ambient temperature range 20 C to 60 C Relative humidity range 80 not condensed...

Page 23: ...on class I Degree of protection IPX4 Protection type Type B Lifting weight 400 kg Lifting height 400 mm Maximum length 2240 mm Maximum width 930 mm Maximum height 1250 1650 mm Time of guarantee 2 year...

Page 24: ...ents All product related information is not subject to change for technical production or other reasons Georg Kr mer Ges m b H Co KG A 4061 Pasching Neuhauserweg 14 Tel 43 0 7229 64450 Fax 43 0 7229 7...

Reviews: