Sound & Vision 

 

The optional feature „Sound & Vision“ can playback mu­
sic files which  are stored on a  USB stick on speakers 
build into the tub body. Furthermore, by means of LEDs 
on different sides it can suffuse the water with light 
in various colours. 

If  this  feature  is  installed  in  your  GK  bathtub,  then 
the  buttons  “PLAY/PAUSE”  and  “LIGHTS”  will  flash 
slowly in a rhythm of 3-4 seconds (ready mode). 
 

Sound 

First of all ensure that a USB stick with readable mu-
sic  files  (mp2,  mp3,  wma)  is  inserted  into  the  USB 
port  (on  the  side  of  the  console).  When  pressing  the 
button  “PLAY/PAUSE”  all  the  recognized  music  files 
will  be  played  back,  sorted  by  name  (and  the  button 
starts to flash faster, about 1x/second). Furthermore, 
the  buttons  “NEXT”  and  “BACK  are  enabled  and  illumi­
nated  continuously.  When  pressing  these  buttons  the 
player  switches  to  the  next  or  previous  (press  2x) 
track. After playing the last track playback continues 
again with the first track. 

By  pressing  the  button  “PLAY/PAUSE”  during  playback, 
it  is  paused  (and  the  button  starts  to  shine  continu-
ously).  When  pressing  it  again,  the  playback  contin-
ues.  In  case  the  pause  exceeds  30  seconds,  the  player 
resets itself to ready mode automatically. Thereafter, 
a  further  playback  would  again  start  at  the  very  be-
ginning.  (In  case  the  USB  stick  gets  pulled  during 
playback or if it was not in the port at the start of 
playback  (the  button  still  flashes  about  1x/second), 
then  this  “empty  playback”  must  be  “paused”  before 
(re-)starting a real playback. 

The  volume  can  be  adjusted  through  the  button  “PLAY/
PAUSE”  in  combination  with  “NEXT”  and  “BACK”.  By 
pressing  the  buttons  “PLAY/PAUSE”  and  “NEXT”  together 
the  volume  is  raised.  By  pressing  the  buttons  “PLAY/
PAUSE” and “BACK” together the volume is lowered. 
 

Vision 

When  pressing  the  button  “LIGHTS”,  the  LED  lights  are 
switched  to  “slow  continuous  colour  change”  mode  (and 
the button starts to flash faster, about 1x/second). - 
When  pressing  the  button  “LIGHTS”  again,  the  colour 
currently  visible  in  that  moment  is  fixed  (and  the 
button  starts  to  shine  continuously).-  Pressing  the 
button a third time will switch back to ready mode and 
the LED lights off. 

Functions 

Summary of Contents for GK Magic 1000

Page 1: ......

Page 2: ...and translation of both the whole document as well as of any parts thereof Congratulations on your decision to purchase a GK Bathtub You have acquired an Austrian quality prod uct which will considera...

Page 3: ...er 8 Setting the temperature 9 Temperature display tub fill shower 9 Underwater light 9 Sound Vision 10 Ultrasound 11 Ultrasound cleaning FAQ 11 13 Hydromassage 14 Shampoo Bath additive 14 Disinfectio...

Page 4: ...ce etc Never leave the patient unattended inside the bathtub Ensure that the equipment is thoroughly cleaned after every use When using disinfection protect your skin and eyes Heed all instructions on...

Page 5: ...4 3 2 1 8 11 10 5 6 7 Components Components 1 Disinfection 2 Lid 3 Shower 4 Control panel 5 Mixer 6 Shampoo Bath additive dispenser 7 Fill in spout 8 Overflow 9 Hydromassage jets 10 Drain 11 Grab han...

Page 6: ...5 Components Hydromassage jet Box for care and disinfection liquids USB port Flowmeter with con centration table...

Page 7: ...Sensor Activation card 6 Button Down 7 Button Up 8 Button Tub fill 9 Button Shower 10 Button Bath additive 11 Button Disinfection 12 Button Shampoo 13 Button Hydromassage Ultrasound 14 Button Underwa...

Page 8: ...oment and locked Only the sensor ACTIVATION CARD is illuminated with a green backlight The standby mode a prevents unauthorized use of the bathtub and b helps to save energy since due to the deactivat...

Page 9: ...n TUB FILL the tub starts filling The button starts flashing and the symbol TUB FILL TEMPERATURE lights up The water now flows into the bathtub until the maximum filling level has been reached or the...

Page 10: ...MPERATURE is illuminated additionally to the flashing button TUB FILL If the shower is active the symbol SHOWER TEMPERATURE is illuminated additionally to the flash ing button SHOWER If tub fill and t...

Page 11: ...on PLAY PAUSE during playback it is paused and the button starts to shine continu ously When pressing it again the playback contin ues In case the pause exceeds 30 seconds the player resets itself to...

Page 12: ...ination of the button stops and it can not be used until the next bathing cycle Note The ultrasound transducer is audible The closer any body parts are to the transducer plate the louder the side nois...

Page 13: ...and spread out through the bathing water What effect does ultrasound have regarding body cleaning Because of the ultrasound millions of tiny gas bubbles are created in the water which collapse again v...

Page 14: ...take unnecessary risks regarding the life of others May the ultrasound cleaning function be applied to people with pacemakers We have no information about any disruption of a pace maker s functionalit...

Page 15: ...massage hose coupling is installed then also the jet containing the coupling will be activated immediately without delay upon activation of the whole function Shampoo Bath additive Both of these prod...

Page 16: ...s infection button is flashing fast 4x sec To start the disinfection procedure take the red hand shower from its holder and press the disinfection but ton The button is flashing now Spray all internal...

Page 17: ...Always check the water temperature with your bare hand also when using the shower before bringing the water in contact with the patient To add bath additive to the water if installed available press t...

Page 18: ...y damage caused by unapproved unsuitable products will not be covered by the manufacturer s warranty Dark grey and transparent plastic parts The dark grey and transparent plastic parts may only be cle...

Page 19: ...h From time to time the hydromassage jet covers should be removed and be cleaned together with the inlet and outlet aper tures separately To do so unscrew the jet covers in counter clockwise direction...

Page 20: ...infection doesn t work and the button is flashing very fast about 4x sec even though the container is full The disinfection sensor is defective and has to be replaced All the functions are disabled ex...

Page 21: ...or other dam ages Caution Should you notice any damage to the bathtub either during maintenance or at any other time then the bathtub may not be used any further from that point onward until the damag...

Page 22: ...0 C Max relative humidity 80 not condensed at 20 C Atmospheric pressure range 500 hPa to 1060 hPa Transport and Storage Ambient temperature range 20 C to 60 C Relative humidity range 80 not condensed...

Page 23: ...on class I Degree of protection IPX4 Protection type Type B Lifting weight 400 kg Lifting height 400 mm Maximum length 2240 mm Maximum width 930 mm Maximum height 1250 1650 mm Time of guarantee 2 year...

Page 24: ...ents All product related information is not subject to change for technical production or other reasons Georg Kr mer Ges m b H Co KG A 4061 Pasching Neuhauserweg 14 Tel 43 0 7229 64450 Fax 43 0 7229 7...

Reviews: