Intended use / For your safety 

■ Intended use 

 
Bathing  system  for  bathing  patients  with  restricted  mobility  in 
care  institutes  and  hospital  wards.  It  is  operated  by  healthcare 
professionals.  The  possible  height  adjustment  provides  an  ergo-
nomic  working  environment  for  the  personnel  and  helps  keeping 
their spines healthy. 
 
 

■ For your safety 

 

 

Ensure  that  this  bathing  system  is  operated  and  maintained 
only by trained personnel. 

 

Always  check  the  water  temperature  with  your  bare  hand  (also 
when  using  the  shower)  before  bringing  the  water  in  contact 
with the patient. 

 

Ensure  that  each  client  is  assessed  for  its  ambulatory  capa-
bility, ensuring the client’s safety when entering and exiting 
the  bathing  system  (utilize  handgrips,  correct  entry  height, 
correct client transferring device, etc.). 

 

Never leave the patient unattended inside the bathtub. 

 

Ensure  that  the  equipment  is  thoroughly  cleaned  after  every 
use. 

 

When  using  disinfection,  protect  your  skin  and  eyes.  Heed  all 
instructions  on  the  disinfectant’s  container  and  material 
safety data sheet. 

 

Always  make  sure  that  the  device  is  supplied  with  power.  It 
may only be interrupted in emergency situations. 

 

Ensure that there are no objects right next to the tub to en-
sure  a  safe  up  and  down  movement.  Disregarding  this  instruc-
tion can cause bad injuries or damage the device. 

 

Don’t  place  any  objects  on  top  of  the  device,  since  due  to 
movement or vibrations, they can fall off - also into the tub. 

 

Adjustments  and repairs  must  be carried  out  by  authorized  and 
appropriately qualified persons only. 

Caution: 

The  safety  rules  and  instructions  in  this  operating 
manual  must  be  observed  in  order  to  ensure  safe  and 
proper  use  of  the  equipment.  All  claims  under  guaran-
tee become void if these requirements are not met. 

Summary of Contents for GK Magic 100

Page 1: ......

Page 2: ...and translation of both the whole document as well as of any parts thereof Congratulations on your decision to purchase a GK Bathtub You have acquired an Austrian quality prod uct which will considera...

Page 3: ...ontrol panel 8 Shower 9 Shampoo Bath additive 9 Underwater light 9 Hydromassage 10 Sound Vision 10 Disinfection 11 12 Flowmeter 11 Manually controlled disinfection procedure model with disinfection va...

Page 4: ...ce etc Never leave the patient unattended inside the bathtub Ensure that the equipment is thoroughly cleaned after every use When using disinfection protect your skin and eyes Heed all instructions on...

Page 5: ...ure 5 Button Hydromassage lights up if configured 6 Button Down with printed arrow 7 Button Bath additive lights up if configured 8 Button Disinfection lights up if configured and needed Control panel...

Page 6: ...Adjustable foot 8 Foot switch 9 Control panel 10 Control panel for Sound Vision 11 Tub fill valve 12 Thermostat mixing valve 13 Fill in spout 14 Shampoo Bath additive dispenser 15 Disinfection valve...

Page 7: ...6 Components Hydromassage jets blue Box for care and disinfection liquids USB port Flowmeter with con centration table...

Page 8: ...y means of the foot switch It works with air pressure and is connected to the electronics through thin air filled plastic tubes The higher air pressure when stepping on the switch activates the corres...

Page 9: ...tion Always check the water temperature with your bare hand also when using the shower before bringing the water in contact with the patient Filling the tub Open the TUB FILL VALVE in counter clockwis...

Page 10: ...a red marking on its suc tion end the tube for the bath additive a blue mark ing at the alike spot If there is no liquid coming out of the system make sure that both boxes are full After installing a...

Page 11: ...2 mp3 wma is inserted into the USB port Now pressing the button PLAY PAUSE will play back all the recognized music files sorted by name Pressing the buttons NEXT and BACK switches to the next or previ...

Page 12: ...irectly on the hand shower and spray all internal tub surfaces with the disinfectant solution Caution Before every disinfection procedure ensure that there is enough disinfectant available in its cont...

Page 13: ...y all internal tub surfaces press the disinfection button again twice Thereby you are restarting the disinfection procedure and have an other 40 seconds available 5 After the 40 seconds are up and spr...

Page 14: ...it to a comfortable working height Once the desired filling level has been reached stop if necessary the inflowing water To add bath additive to the water if installed press the button BATH ADDITIVE f...

Page 15: ...p We especially recommend our special plastics intensive cleanser details on request For these parts of the tub only use very fine textured chamois leather or a microfiber cloth For the best care for...

Page 16: ...ed cover of the thermostatic mixing valve Also the cartridge could be defective and might have to be changed The display reads F0 or F1 The temperature sensor is defective and must be changed Very lit...

Page 17: ...d of the disinfection shower hose as well as of any externally visible connections Once a month check the bathtub for any cracks or other dam ages Caution Should you notice any damage to the bathtub e...

Page 18: ...0 C Max relative humidity 80 not condensed at 20 C Atmospheric pressure range 500 hPa to 1060 hPa Transport and Storage Ambient temperature range 20 C to 60 C Relative humidity range 80 not condensed...

Page 19: ...class I connection of protective earth conductor necessary Degree of protection IPX4 Protection type Type B Lifting weight 400 kg Lifting height 400 mm Maximum length 2240 mm Maximum width 930 mm Max...

Page 20: ...Tel 43 0 7229 64450 Fax 43 0 7229 70664 service gk medizinmechanik at www gk medizinmechanik at Typing spelling or transmission errors excepted for all contents All product related information is not...