Care & Cleaning of the tub 

■ Care & Cleaning of the tub 

 

Caution: 

Any  product  used  to  clean  or  disinfect  your  GK  bath 
must  be  free  from  any  abrasive,  alcohol  &  corrosive 
ingredients.  Never  use  any  kind  of  customary  glass 
cleansers,  solvents  (e.g.  acetone)  or  similar  deter-
gents  or  dilutions.  Never  use  harsh  or  pointed  uten-
sils,  e.g.  rough  clothes,  scrubbing  sponges,  scouring 
pads or any tools. If you are in any doubt about your 
usual  cleaning  products  please  contact  your  GK  repre-
sentative before use.   
 
Any  damage  caused  by  unapproved  /  unsuitable  products 
will not be covered by the manufacturer’s warranty. 

 
For cleaning, after use always rinse the bath tub thoroughly with 
the  shower  hose.  Any  dirt  which  adheres  to  the  bathtub  surfaces 
must  be  removed  with  a  soft  sponge  or  cloth  and,  if  necessary, 
customary  detergents  (besides  the  above  mentioned  restrictions). 
Always clean the plastic parts wet or damp but never dry. 
 

We recommend using our approved shampoo and bath additive products 
with  your  GK  bath. 

Other  products  may  cause  more  persistent  dirt 

being harder to clean. 
 

We also recommend for you to polish the white bath tub body once a 
month with car polish cream.

 This will give the bathtub a smooth, 

water  repellent  surface  and  will  make  routine  cleaning  considera-
bly easier – it will also enhance the appearance of your GK bath. 
 

Once  in  a  while,  the  door  seal  should  be  treated  with  talcum  to 
give  the  seal  a  smooth  surface.  This  way  the  door  will  not  stick 
to the door frame. 

 
A disinfection cycle should always be performed after cleaning. 
 

Where fitted, the jet coverings should also be 
cleaned & disinfected (see pictures). 
 
To  do  that,  unscrew  the  jet  cover  anti-
clockwise. Now clean the cover, the inlet aper-
ture and the outlet aperture thoroughly. 
 
Re-assemble the jet cover by rotating it clock-
wise. 

 

Note:

 

 

Do not use excessive force! 

 

If  you  have  any  further  questions  or  require 
more  information  please  contact  your  local  GK 
representative, who will be happy to advise. 

Summary of Contents for GK Hera

Page 1: ......

Page 2: ...1...

Page 3: ...ating the hydro massage 5 Adjusting the massage intensity 5 Bath additive and shampoo dispenser 5 Handling the shower 5 Draining the bathtub 5 Opening the door 6 Handling the disinfection 6 Flowmeter...

Page 4: ...iner and material safety data sheet Mains power to the bath should NEVER be isolated except when necessary for routine maintenance servicing Don t deposit any things on the bathtub Because of movement...

Page 5: ...ts wet or damp but never dry We recommend using our approved shampoo and bath additive products with your GK bath Other products may cause more persistent dirt being harder to clean We also recommend...

Page 6: ...temperature by turning the thermal mixing valve L located in the centre of the control panel pic 4 The current tub fill or shower temperature is shown on the digital display M above the valve Activati...

Page 7: ...select maximum temperature Now use the white hand shower to rinse all disinfected parts thoroughly also the mas sage nozzles as done before with the red hand shower To com plete the procedure press th...

Page 8: ...disinfection sensor is defective and has to be replaced No bath additive or shampoo appears by pressing the buttons The corresponding box is empty or there is air in the system Re place the container...

Page 9: ...s of the build in hoist the detachable seat and the separate chassis Ensure that the jet coverings of the hydro massage system have been cleaned regularly Caution In the event of detected damage do no...

Page 10: ...l environ ment by trained and competent personnel Standards regulations The bathtub complies with the essential requirements pursuant to Appendix I of the Medical Device Directive 93 42 EEC In accorda...

Page 11: ...es 3 15 A time delay 3 A time delay 5 A time delay at 115 V 15 A time delay 6 3 A time delay at 115 V Protection class I Degree of protection IPX4 Protection type Type B Overall length 1510 mm Overall...

Page 12: ...o 60 C Relative humidity range 80 not condensed at 20 C Atmospheric pressure range 500 hPa to 1060 hPa Recycling Package Wood and corrugated cardboard recyclable Product Electric steel and plastic par...

Page 13: ...12 Notes Notes...

Page 14: ...Notes Notes 13...

Page 15: ...Notes 14 Notes...

Page 16: ...Tel 43 0 7229 64450 Fax 43 0 7229 70664 service gk medizinmechanik at www gk medizinmechanik at Typing spelling or transmission errors excepted for all contents All product related information is not...

Reviews: