Operating and use. Inteli Control
103
Code no. 550038
Rev. no. 16/1018
Operation parameters
LANGUAGE
Permits selecting the language of all the written messages.
Programmable values
...........
ESP (Spanish) | ENG (English) | FRA (French) | DEU (German) | POR
(Portuguese)
Factory settings
......................
depending on specification
Value by default
.....................
Spanish
SCREEN CONTRAST
Permits modifying the contrast on the ironer screen.
Programmable values
............
0 (less contrast) ... 9 (more contrast)
Factory settings
.......................
5
FIELD OF USAGE
Adapts ironing programs and operating parameters to certain fields of use.
Programmable areas
..............
General | USA
Factory settings
.......................
depending on specification
Value by default
......................
General
TEMPERATURE UNIT
Permits selecting the unit that the temperature values are displayed.
Programmable values
............
C
(Celsius degrees)|
F
(Fahrenheit degrees)
Factory settings
.......................
depending on specification
Value by default
......................
degrees Celsius
SPEED UNIT
Allows the user to select the unit in which the speed of the rolls will be shown.
Programmable values
............
m
/
min
(metres per minute) |
ft
/
min
(feet per minute)
Factory settings
.......................
depending on specification
Value by default
......................
metres per minute
BEEP WHEN PRESSING THE KEY
When pressing a key, the microprocessor emits an acoustic beep. This beep can be annulled.
Programmable values
...........
YES / NO
Factory settings
......................
YES
SHUT DOWN
An option available only on machines with folder options or SHUT DOWN active in the SETUP menu.
Reduces the speed and switches off the heating system on detecting that a certain time has elapsed without
linen being inserted.
Programmable values
...........
YES / NO
Factory settings
......................
NO
NETWORK IDENTIFIER
This parameter assigns a network identifier to the ironer. This identifier enables the communication of the
ironer with the environment through a protocol based on RS-485.
Programmable values
...........
0 (disabled communication) / 1..99 (enabled communication)
Factory settings
......................
0
(For further information, see the Communication Protocol Instruction Manual)
OPTIFEED LIGHT INTENSITY
Allows the user to select the intensity of the lights for the linen feeding table.
Option available by activating
Board A4
in the SETUP menu.
Programmable values
.........
OFF / 10-20-
30…………100%
Factory settings
....................