Program execution mode
19
Cod. 598144
Rev. 11/0717
4.7. Stop modes
4.7.1. End of cycle and door opening
The
End
report will be displayed.
The buzzer and the LED indicating the end of the cycle inform that the program has finished and the door lock is
released.
From this moment on, the door can be opened.
Failure in the realising of the door
At the end of a cycle, if the end of cycle warning LED is not illuminated or a countdown of 120 seconds appears
on the display, push the door firmly using the handle and press any key on the keyboard to start a new attempt at
unlocking the safety lock.
If the problem persists, wait for a minimum of three minutes until the thermal locking device allows the door to
unlock.
4.7.2. Pressing the STOP key
Pressing the
interrupts the programme being executed.
The drum stops rotating and the drain valve opens.
At the end of the safety delay, the buzzer informs the user that door lock is unlocked and the display shows
STOP
– PUSH – Pr-*
(number of program being executed).
From this moment onwards:
One press on the key corresponding to the program currently being executed resumes the cycle.
Opening the door cancels the cycle.
STOP key operating options
A parameter from the
CONF
menu can be used to select two different options for operating the
STOP
key.
Selectable options:
Immediate response
Pressing the
STOP
key immediately stops the program that is running.
Delayed response
To stop the program that is running, hold the key down continuously for at least 3 seconds.
Warnings regarding the HOLD STOP KEY DELAYED RESPONSE
Option available on machines with software Version 31 / 65 and later (see Section 1).
Option unavailable in machines configured for Japan Area of use.
To use this operating option, the corresponding parameter must be enabled in the machine’s
CONFIGURATION menu. This operation must be carried out by the Authorised Technical
Service.
The HOLD STOP KEY DELAYED RESPONSE option can only be activated on machines that
have the message “Push and hold for 3 seconds” inscribed next to the STOP key.