Disconnect the connection between the Radio Bus transmitter and the eNet actuator
Figure 6: Disconnecting
o
Press the
Prog
button (3) of the gateway for longer than 4 seconds.
The status LED flashes after 4 seconds. The gateway is in programming mode for
approx. 1 minute.
o
Also switch all the eNet Bus actuators to be disconnected to programming mode (see eNet
actuator instructions).
o
Press the connected channel button on the Radio Bus transmitter for longer than one
second or the scene button for longer than three seconds.
The connection to the eNet actuator is disconnected. The LED of the actuator flashes
quickly.
The eNet actuator is disconnected. The actuator exits programming mode automatically.
Resetting the device to the factory setting
All the connections in the gateway between transmitters and actuators are disconnected.
Recommissioning must take place.
i
Before resetting to the factory setting, disconnect connected Radio Bus actuators (see
Disconnecting the connection to the Radio Bus actuator). This ensures that setting up new
connections does not cause unintentional switching operations.
o
Press the
Prog
button for at least 20 seconds.
The status LED flashes after 4 seconds. After 20 seconds the status LED flashes faster.
o
Release the
Prog
button and press it once again within 10 seconds.
All the connections are disconnected. The status LED flashes more slowly for approx. 5
seconds.
5 Appendix
5.1 Technical data
Rated voltage
AC 230 V ~
Mains frequency
50 / 60 Hz
Rated load current
16 A (I
L
)
Power consumption
max. 1 W
Degree of protection
IP 20
Ambient temperature
-5 ... +45 °C
Dimensions W×H×D
57×127×78 mm
Transmitting range in free field
typ. 100 m
Receiver category
2
32582112
10865123
11.04.2017
6/8