4.2 eNet transmitter controls Radio Bus actuators
i
Commissioning is not possible via the eNet server.
Connecting the eNet transmitter with the Radio Bus actuator
Figure 3: Connecting the eNet transmitter
Connection takes place in two steps (Figure 3). Step A: Connect the eNet transmitter with the
gateway.
Step B: Connect the eNet transmitter to one or more Radio Bus actuators.
Step (A):
o
Press the
Prog
button (3) of the gateway for longer than 4 seconds.
The status LED flashes after 4 seconds. The gateway is in programming mode for
approx. 1 minute.
o
Switch the eNet transmitter to programming mode as well (see eNet transmitter
instructions).
o
Briefly press the channel or scene button of the eNet transmitter.
The status LED of the gateway lights up for approx. 5 seconds.
The gateway and eNet transmitter exit the programming mode automatically.
Step (B):
o
Switch one or more Radio Bus actuators to programming mode (see Radio Bus actuator
instructions).
o
Press the channel button of the eNet transmitter for longer than one second or the scene
button for longer than three seconds.
The LEDs of the Radio Bus actuators light up.
The eNet transmitter is connected to the Radio Bus actuators.
o
Exit the programming mode of the Radio Bus actuators (see Radio Bus actuator
instructions).