background image

4.2 eNet transmitter controls Radio Bus actuators

i

Commissioning is not possible via the eNet server.

Connecting the eNet transmitter with the Radio Bus actuator

Figure 3: Connecting the eNet transmitter

Connection takes place in two steps (Figure 3). Step A: Connect the eNet transmitter with the
gateway.
Step B: Connect the eNet transmitter to one or more Radio Bus actuators.
Step (A):

o

Press the 

Prog

 button (3) of the gateway for longer than 4 seconds.

The status LED flashes after 4 seconds. The gateway is in programming mode for
approx. 1 minute.

o

Switch the eNet transmitter to programming mode as well (see eNet transmitter
instructions).

o

Briefly press the channel or scene button of the eNet transmitter.
The status LED of the gateway lights up for approx. 5 seconds.
The gateway and eNet transmitter exit the programming mode automatically.

Step (B):

o

Switch one or more Radio Bus actuators to programming mode (see Radio Bus actuator
instructions).

o

Press the channel button of the eNet transmitter for longer than one second or the scene
button for longer than three seconds.
The LEDs of the Radio Bus actuators light up.
The eNet transmitter is connected to the Radio Bus actuators.

o

Exit the programming mode of the Radio Bus actuators (see Radio Bus actuator
instructions).

32582112

10865123

11.04.2017

3/8

Wireless converter intermediate plug

Summary of Contents for eNet 5323 02

Page 1: ...d must remain with the end customer 2 Device components Figure 1 Gateway 1 SCHUKO socket with increased contact protection 2 Red status LED covered 3 Button Prog 3 Function Intended use Control of eNe...

Page 2: ...sible using the wireless converter Scenes 6 16 Threshold value functions and disabling functions Save switch on brightness using transmitter Transmission status and status feedbacks 4 Information for...

Page 3: ...ter to programming mode as well see eNet transmitter instructions o Briefly press the channel or scene button of the eNet transmitter The status LED of the gateway lights up for approx 5 seconds The g...

Page 4: ...than three seconds The connection to the Radio Bus actuator is disconnected The LED of the actuator flashes quickly o Exit the programming mode of the Radio Bus actuators see Radio Bus actuator instru...

Page 5: ...eact to the channel or scene button to programming mode as well see eNet actuator instructions i Up to 10 eNet actuators can be connected at the same time o Press the channel button on the Radio Bus t...

Page 6: ...teway between transmitters and actuators are disconnected Recommissioning must take place i Before resetting to the factory setting disconnect connected Radio Bus actuators see Disconnecting the conne...

Page 7: ...setting On With this device the parameter has no function Sum status transmission repetitions On Off Transmit 2x 11x Off Transmit 4x without connection Basic setting Off With this device the parameter...

Page 8: ...son specialist trade installation company electrical specialist trade They will forward the devices to the Gira Service Center Gira Giersiepen GmbH Co KG Elektro Installations Systeme Industriegebiet...