Labelling

Function

Audio R in

Input, audio signal, right

Audio L in

Input, audio signal, left

Audio GND

GND audio inputs

Audio R out

Output, audio signal, right

Audio L out

Output, audio signal, left

Audio GND

GND audio outputs

Video in

Input, video signal

Video GND

GND video signal

Table: Connection assignment, audio and video connections

Use the Ethernet connection (32) together with the supplied Ethernet adapter plug and Ethernet
adapter cable to connect to the IP network.
Pay attention to the correct colour assignment of the wires, EIA/TIA-568-A or -B. This can be
found in the documentation of the installed network components and routers. 

i

The Ethernet connection on the device is carried out according to EIA/TIA-568-B.

o

Connect Ethernet cable to the Ethernet adapter plug. To do this, strip the Ethernet wires,
do not skin, and insert into the cover of the adapter plug. Shorten any wires that are jutting
out and push the cover onto the adapter plug in the correct position (Figure 7).

o

Connect the supplied Ethernet adapter cable to the terminal (32) and Ethernet adapter
plug.

Figure 7: Connection of adapter connector to Ethernet cable 

o

Install device in panel-mounted housing. Use the screws supplied.

o

Insert the Design frame in the correct direction into the designated brackets and push down
and to the left - down and to the right for vertical mounting - to fix it.

5.2 Commissioning

Control 9 KNX: Loading physical address

o

Press the programming button (9).
The programming LED (8) lights up.

o

Assign physical address.
The programming LED (8) goes out.

Control 9 KNX: Loading the application software

i

The project design and commissioning are performed using external project design and
commissioning software.

o

Establish connection to the commissioning PC via IP connection.

82576732

03.06.2016

8/11

KNX

Control 9 Client, Control 9 KNX

Summary of Contents for Control 9 Client

Page 1: ...device before working on it At the same time take into account all circuit breakers that supply dangerous voltage to the device Do not operate the device with sharp or pointed objects The touch sensi...

Page 2: ...unction of this device depends upon the software Detailed information on loadable software and attainable functionality as well as the software itself can be obtained from the manufacturer s product d...

Page 3: ...um touch sensitivity Keep the screen free of foreign bodies and dust Use a soft lint free cloth to clean the screen If needed moisten the cleaning cloth slightly i Do not use sharp cleaning agents aci...

Page 4: ...o called touchscreen The device is operated by touching the screen surface with a finger or a special touchscreen stylus not included in the scope of delivery i Do not operate the touchscreen with sha...

Page 5: ...tarted The previous data is restored is the device is switched off or there is a power failure Changes to the My Documents directory are excluded from write protection and are always applied The write...

Page 6: ...ting the device Figure 4 Rear side Connections 31 KNX connection only for Control 9 KNX 32 Ethernet connection 33 Mains connection 34 Ventilation openings 35 Connection for Audio input and output 36 C...

Page 7: ...voltage and low voltage are located in a shared appliance box If there is an error other connected components may carry mains voltage Electrical shocks can be fatal Always secure the mains voltage wi...

Page 8: ...not skin and insert into the cover of the adapter plug Shorten any wires that are jutting out and push the cover onto the adapter plug in the correct position Figure 7 o Connect the supplied Ethernet...

Page 9: ...n class II System Processor type Intel AtomTM Z510 Clock speed 1 1 GHz L2 cache 512 kB System chipset Intel System Controller Hub US15W Mass storage 2 GB SSD RAM 1 GB RAM Audio controller Realtek ALC8...

Page 10: ...Idle power Pidle 16 6 W Power in idle state Psleep 0 93 W Power in off state Poff 0 73 W Noise level 6 dB A Measurement method Test voltage 230 V Distortion factor of the test voltage 1 6 Power measu...