Installation and start-up
20
06.2017/V 1.2
2.10 Error
signalling
2.10.1 Weak battery
2.10.2 Loss of radio connection
Device display
with weak battery
Call module display
Possible cause:
weak battery.
Eliminate the cause:
New battery, see 3.7.
Result:
Device display
Call module display
Possible cause (see 2.1):
•
e.g. unsuitable installation location
•
e.g. unsuitable climatic conditions
(humidity)
•
e.g. unsuitable distance between the
call module and the other devices
Eliminating the cause:
•
e.g. select a suitable installation location
•
e.g. create suitable climatic conditions
(low humidity)
•
e.g. ensure more suitable distance
between the call module and other
devices
Result:
Flashes
1 x short
Flashes
1 x short
Pause
5 sec.
Flashing frequency:
2 Hz
The LED goes out
The LED goes out
Flashes
1 x short
Flashes
1 x short
Pause
5 sec.
Flashing frequency: 1 Hz
The LED goes out
The LED goes out