2.4.3 On-site Commissioning Adjustment
• Ensure the regulator supplied is fitted and the correct inlet gas pressure is adjusted
• From the specification table listed on the previous page please adjust the RQ screw the
nominated turns from closed
• Once the unit has been installed and all installation instructions followed please turn the unit on
- Ensure the cavity is empty of all packaging items
• Testing is completed once the burner is operating continuously without any flame failures
- Flame failure is likely due to air still being in the gas supply line
Adjust RQ screw as indicated in the table (Page 9)
Gas Test Procedure:
A. Press “Settings”
B. Press “Service”
C. Press “Advanced Services”
D. Type the password 156 then press Enter to confirm
E. Press “Gas Test”
F. The gas test must be carried out with the door open
G. Phase 1 - Burner Off. Press “Forward” to begin the gas test procedure
H. Phase 2 - Burner ignition
I. Phase 3 - Minimum / Maximum power. Press “Back/Forward” to toggle between Minimum / Maximum.
Pressing forward when in the Maximum will end the procedure
A
C
B
E
F
H
G
I
For connection using a flexible hose assembly, the flexible hose assembly must be certified to AS/NZS 1869 class B or D, be of appropriate
internal diameter for the total gas consumption, be kept as short as possible (not exceeding 1200mm), must not be in contact with the floor or
any hot or sharp surfaces. The hose assembly must not be subject to strain, abrasion, kinking or deformation.
A restraining device must be fitted to restrict the appliance movement to no more than 80% of the gas hose length.
Annual service by an authorised person is recommended, or if any of the following conditions are noticed; incomplete ignition, appreciable
yellow tipping, carbon deposition, lifting, floating, lighting back or objectionable odour.
2.0 Installation
D