Page 22
Due to continuous product research and development,
the information contained herein is subject to change without notice.
www.stoddart.com.au
www.stoddart.co.nz
700/900
Symbol
Description
Short circuit inductance sensor, induction temperature too low (lower than -50°C) (shown every 5 seconds if the hob is off)
Induction temperature too high, temperature sensor off >260°C
Pan seek, pan missing or pan too small
Incompatible pan, inductance short circuit (μh value too low)
Dissipater temperature > 100°C or dissipater sensor short circuit
Dissipater temperature < -15°C or dissipater sensor short circuit
Potentiometer missing or defective: value error (>10.75 kΩ)
With the dial in the OFF position, residual temperature indicator (temp. Cooking zone >45°C)
External display missing (off or SW1/3 on) or inductance temperature too high, temperature sensor interruption > 260°C
Switch on after power failure phase L1 and L3 to 0 <150V (the hob works with limited power if phase L2 is absent)
IO DEVICE 1 or 2 missing (possible display breakage)
Caution: DC current >350 mA (too many fans or fan error)
Caution: fan blocked or disconnected (5” after switching on, then every 10” for 1’)
Over voltage on inductance. Switch the hob off and then on again.
5.0 Cleaning and Maintenance
5.2.3 Error Codes