GSR 36/48 is a   control circuit for   photovoltaic (PV) panels to 
battery   charge.   GSR   36/48   V   implement   PV   panels   step   up 
tension circuit (

Step-up

) it can so work with PV panels having 

a working voltage inferior to the voltage of the battery. In fig. 1 
it is possible to find a complete GSR 36/48 V scheme. 
The charging circuit of the battery makes the PV module work 
in   the   maximum   power   point   in   a   voltage   range   from   2.0V 
down to a voltage close to the battery voltage . The battery can 
be both 36V and 48V, and the voltage can be changed using a 
switch. 
The GSR 36/48 can be configured to charge lead-acid batteries 
(charge - end voltage, temperature compensated) and lithium- 
ion battery (LiFePo) and in this case applies a constant charge - 
end voltage with temperature.
There   is   a   LOAD   terminal   that   can   be   used   to   control   the 
activation   of   an   external   load   at   the   same   voltage   of   the 
battery with a maximum current of 5A.
The   LOAD   terminal   can   be   configured   using   a   dip   switch   to 
fuction for 24 h/day or it can be set to function only at night 
(SW3).
The   LOAD   terminal   doesn't   function   in   case   of   low   battery 
(voltage lower than the low-battery signal- see Tab 3).
Two LEDs on the GSR 36/48 indicate the operational status of 
the   system   ,   a   green   LED   indicates   the   charging   current 
delivered to the battery , while an amber/red LED indicates a 
low battery condition or overtemperature (see Tab.2).

MPPT step-up recharge

Large tension range on panel  

entrance V

p

 = 2.0V –V

batt

Battery tension 36V / 48V  with 

dipswitch sortable

For Pb and Lithium ions batteries 

with dipswitch sortable

Temperature compensated Charge 

voltage

Over temperature protection

Protection for battery polarity 

inversion 

Case in ABS.

  

  

  

  

This document is the property of  

Giocosolutions S.r.l. 

1

Summary of Contents for GSR 36/48V

Page 1: ...ith temperature There is a LOAD terminal that can be used to control the activation of an external load at the same voltage of the battery with a maximum current of 5A The LOAD terminal can be configured using a dip switch to fuction for 24 h day or it can be set to function only at night SW3 The LOAD terminal doesn t function in case of low battery voltage lower than the low battery signal see Ta...

Page 2: ...GSR 36 48V Technical manual Model 36 48 Working scheme Fig 1 working scheme This document is the property of Giocosolutions S r l 2 ...

Page 3: ...electrical connections as shown in Fig 2 First of all connect the Load then the battery and last the PV module If this sequence is respected the GSR may signal a battery error red led stable be sure to use the electric cables to the appropriate section of current that must flow As soon as the battery is connected both LEDs light up for a second to report good start to the charge controller 6 Test ...

Page 4: ...tteria SW2 OFF Select lead acid battery with compensation of end of charge voltage in temperature as shown in fig 3 SW2 ON Select li ion battery with end of charge voltage of 43 2V for 36V systems and 57 6V for 48V systems Dip switch 3 Posizione Configura accensione carico LOAD SW3 OFF Load terminal working 24 h day SW3 ON Load terminal working only at night Tab 1 Dip switch configuration This doc...

Page 5: ...ec 2 0A current 2 5A 6 flashes every 8 sec 2 5A current 3 0A 7 flashes every 8 sec current 3 0A Led Status Amber Functionality Indicates the state of the system STATUS Led color amber indicates the activation of the load terminal 1 flash red every 8 seconds signals Low Battery In these conditions the load terminal is unactive Led color red indicates error of battery Tab 2 Led Signals End of charge...

Page 6: ...tt Vtadj 72mV C 96mV C End charge voltage at 25 C program Lithium SW2 ON Vch_Li 43 2V 57 6V Low battery voltage warning Vlb_Pb 33 3V 44 4V Voltage output signal low battery Vout_lb_ Pb Vch_Pb 1 2V Vch_Pb 1 6V Self consumption Vlb Li 37 5V 50 0V Operating Temperature Vout_lb Li Vch_li 1 2 V Vch_li 1 2V Power dissipation Iload 5A 5A Section terminals VLoad Vbatt Vbatt Degree of protection Isleep 10m...

Page 7: ... delivered to an authorized collection center or in case of purchase of equivalent equipment can be returned free of charge to the distributor of the new equipment The penalties for those who illegally gets rid of electronic waste will be applied by the individual municipalities Giocosolutions s r l Via Avogadro 19 Avigliana 10051 To Italy info giocosolutions com www giocosolutions com This docume...