background image

GSR 36/48V 

Technical manual

  

   

Model 36/48

       Electrical connection and plugging

1 ) Set the DIP switch 1 according to the voltage of the battery in use 36 V or 48 V.
If the GSR 36/48 is powered by an incorrect  configuration of the dip switch can ruin the  
battery or not function properly.

          2 ) Set the DIP switch 2 according to the type of battery (Pb or LiFePo ) as described in the 

following table 1 ( configuration dip-switch) . If the GSR 36/48 is powered by an incorrect 
configuration of the dip -switch can ruin the battery or not function properly.

3 ) Set the DIP switch 3 according to the type of LOAD expected, 24 h or at night.

4) Install the GSR 36/48 in a dry place , not exposed to rain and adequately ventilated. 
During its operation the GSR 36/48 generate more heat and keep warm , to prevent entry 
into operation its overtemperature protection you need to keep a clear space around it so 
that it can circulate air that helps cooling.

5) Make the electrical connections as shown in Fig. 2,
First of all connect the Load, then the battery and last the PV module. If this sequence is   
respected the GSR may signal a battery error( red led stable).

 

be sure to use the electric cables to the appropriate section of current that must flow . As 
soon as the battery is connected both LEDs light up for a second to report good start to 
the charge controller.

6 ) Test the installation just connected by verifying that the system charges the battery. 
With  the  PV  module  exposed  to  good   light  ,  verify   that  the  green   LED   is  flashing,   it  
indicates that charging current is flowing into the battery. For a closer examination of the 
proper   functioning   of   the   regulator   is   recommended   to   check   with   a   voltmeter   while  
charging the battery voltage measured at the terminals of the PV module PV + and GND is 
close   to   the   maximum   output   voltage   of   the   photovoltaic   module   in   use   (   see   the  
datasheet module to locate the voltage of maximum power typically referred to as Vmp . 
During this test, make sure the battery has a voltage lower than the voltage - end load 
set.

This document is the property of  

Giocosolutions S.r.l. 

3

Summary of Contents for GSR 36/48V

Page 1: ...ith temperature There is a LOAD terminal that can be used to control the activation of an external load at the same voltage of the battery with a maximum current of 5A The LOAD terminal can be configured using a dip switch to fuction for 24 h day or it can be set to function only at night SW3 The LOAD terminal doesn t function in case of low battery voltage lower than the low battery signal see Ta...

Page 2: ...GSR 36 48V Technical manual Model 36 48 Working scheme Fig 1 working scheme This document is the property of Giocosolutions S r l 2 ...

Page 3: ...electrical connections as shown in Fig 2 First of all connect the Load then the battery and last the PV module If this sequence is respected the GSR may signal a battery error red led stable be sure to use the electric cables to the appropriate section of current that must flow As soon as the battery is connected both LEDs light up for a second to report good start to the charge controller 6 Test ...

Page 4: ...tteria SW2 OFF Select lead acid battery with compensation of end of charge voltage in temperature as shown in fig 3 SW2 ON Select li ion battery with end of charge voltage of 43 2V for 36V systems and 57 6V for 48V systems Dip switch 3 Posizione Configura accensione carico LOAD SW3 OFF Load terminal working 24 h day SW3 ON Load terminal working only at night Tab 1 Dip switch configuration This doc...

Page 5: ...ec 2 0A current 2 5A 6 flashes every 8 sec 2 5A current 3 0A 7 flashes every 8 sec current 3 0A Led Status Amber Functionality Indicates the state of the system STATUS Led color amber indicates the activation of the load terminal 1 flash red every 8 seconds signals Low Battery In these conditions the load terminal is unactive Led color red indicates error of battery Tab 2 Led Signals End of charge...

Page 6: ...tt Vtadj 72mV C 96mV C End charge voltage at 25 C program Lithium SW2 ON Vch_Li 43 2V 57 6V Low battery voltage warning Vlb_Pb 33 3V 44 4V Voltage output signal low battery Vout_lb_ Pb Vch_Pb 1 2V Vch_Pb 1 6V Self consumption Vlb Li 37 5V 50 0V Operating Temperature Vout_lb Li Vch_li 1 2 V Vch_li 1 2V Power dissipation Iload 5A 5A Section terminals VLoad Vbatt Vbatt Degree of protection Isleep 10m...

Page 7: ... delivered to an authorized collection center or in case of purchase of equivalent equipment can be returned free of charge to the distributor of the new equipment The penalties for those who illegally gets rid of electronic waste will be applied by the individual municipalities Giocosolutions s r l Via Avogadro 19 Avigliana 10051 To Italy info giocosolutions com www giocosolutions com This docume...

Reviews: