3. Overview

3.1 Front Panel Display

Figure 3.1 Front Panel Display

3.2 LED Status Indicator Lights

There are three LED status indicator lights in the front panel of the inverter.  Left LED: 
POWER LED (red) indicates the power status of the inverter. Middle LED: OPERATION
LED (green) indicates the operation status. Right LED: ALARM LED (yellow) indicates 
the alarm status. Please see Table 3.1 for details

Description

The inverter can detect DC power

No DC power or low DC power

The inverter is operating properly.

The inverter has stopped to supply power.

The inverter is initializing.

Alarm or fault condition is detected.

The inverter is operating properly.

Status

ON

OFF

ON

OFF

OFF

ON

FLASHING

Light

POWER

OPERATION

ALARM

Table 3.1 Status Indicator Lights

2.Safety Instructions

2.3 Notice For Use

The inverter has been constructed according to the applicable safety and technical 
guidelines. Use the inverter in installations that meet the following sepcification ONLY:

1. Permanent installation is required.

2. The inverter must be connected to a separate grounded AC group, to which no other 

    electrical equipment is connected.

3. The electrical installation must meet all the applicable regulations and standards. 

4. The inverter must be installed according to the instructions stated in this manual.

5. The inverter must be installed according to the correct technical specifications.

6. To startup the inverter, the Grid Supply Main Switch (AC) must be switched on, before

   the solar panel's DC isolator shall be switched on. To stop the inverter, the Grid Supply 

   Main Switch (AC) must be switched off before the solar panel's DC isolator shall be 

   switched off.

CAUTION:

 

The PV array (Solar panels) supplies a DC voltage when it is exposed to light.

CAUTION: 

Risk of electric shock from energy stored in capacitors of the Inverter. Do not 
remove cover until 5 minutes after disconnecting all sources of supply. Service
technician only. Warranty may be voided if any unauthorized removal of cover.

CAUTION: 

The surface temperature of the inverter can reach up to 75

 (167 F).

To avoid risk of burns, do not touch the surface when inverter is operating. 
Inverter must be installed out the reach of children.

WARNING: 

To reduce the risk of fire, branch-circuit over-current protective devices
 (OCPD) are required for circuits connected to the Inverter. 
The recommend rated trip current for AC breaker should be 25A for Solis-6K 
inverter, 32A for Solis-10K, Solis-15K, Solis-20K-HV inverter.

CAUTION: 

Risk of electric shock. Do not remove cover. There is no user serviceable 
parts inside. Refer servicing to qualified and accredited service technician.

.7.

.6.

Summary of Contents for Solis-10K

Page 1: ...PV Grid Tie Inverter Installation and Operation Manual Ver 2 6 Solis Three Phase Inverter...

Page 2: ...ont Panel Display 3 2 LED Status Indicator Lights 3 3 Keypad 3 4 LCD 4 Installation 4 1 Selecting Location for the Inverter 4 2 Mounting the Inverter 4 3 Electrical Connections 5 Start and Stop 5 1 St...

Page 3: ...240V three phase grid system All 6 models are transformerless topology grid tie PV inverter Figure 1 1 Front side view 3 Figure 1 2 Bottom side view 6 Operation 6 1 Main Menu 6 2 Information 6 3 Sett...

Page 4: ...WARNING symbol indicates important safety instructions which if not correctly followed could result in serious injury or death Improper use may result in potential electric shock hazards or burns This...

Page 5: ...The inverter must be installed according to the instructions stated in this manual 5 The inverter must be installed according to the correct technical specifications 6 To startup the inverter the Gri...

Page 6: ...fault indications 8 9 To select a location for the inverter the following criteria should be considered To avoid over heating ambient air temperature MUST be considered when choosing the inverter ins...

Page 7: ...500mm 500mm 500mm 500mm Figure 4 1 Inverter Mounting clearance 4 Installation 4 Installation Inverter should be mounted in a vertical position as shown in Figure 4 3 The steps to mount the inverter on...

Page 8: ...itting the hooks into the slot of the bracket Use M4 14 stainless steel screws at holes E and F in Figure 4 to secure the mounting hooks to the rear of the inverter Figure 4 4 Wall Mount Bracket The e...

Page 9: ...4 8 Insert the Wire into the Connector Cap nut and contact pin Figure 4 10 Connector with Cap nut Screwed on Figure 4 11 Connect the DC Connectors to the Inverter v Then connect the DC connectors to t...

Page 10: ...of AC wire about 8mm Insert the cable through the jacket and cap nut of connector then insert the wires to the grid terminal and tighten the screws on the connector as shown in Figure 4 13 Please try...

Page 11: ...Solis 15K Figure 5 1 Company Name and Inverter Model on LCD 3 When both the DC and the AC grid sides supply to the inverter it will be ready to generate power Initially the inverter will check both i...

Page 12: ...n by scrolling up or down 6 Operation Pressing the ESC key returns to the Main Menu Pressing the ENTER key to lock Figure 6 2 a or unlock Figure 6 2 b the screen V_DC1 350 8V I_DC1 5 1A V_DC2 350 8V I...

Page 13: ...cation purpose The address number can be assigned from 01 to 99 see Figure 6 4 The default address number of Solis three phase inverter is 01 6 Operation 23 22 6 4 Advanced Info Technicians Only Selec...

Page 14: ...E Before to using this function please set GRID OFF to stop inverter refer to Section 6 5 2 NOTE The inverter is customized according to the local standard before shipping to the customer The User Def...

Page 15: ...ues of the User Def standard are some reference values They are not indicating the values of the standard you are currently using Press the UP DOWN keys to scroll through items Press the ENTER key to...

Page 16: ...Trouble Shooting Alarm Message OV G V UN G V OV G F UN G F G IMP NO GRID OV DC OV BUS UN BUS GRID INTF INI FAULT OV TEM GROUND FAULT Failure description Over grid voltage Under grid voltage Over grid...

Page 17: ...59 3 AS4777 VDE 0126 1 1 VDE 4105 CEI 0 21 CQC 31 30 9 Specifications Operating Range Utility Frequency Model The max DC input voltage MPPT operation range The max dc input current Number of MPPT stri...