background image

5. Inverter monitoring Connection.
   
The inverter can be monitored by Wi-Fi or GPRS functions. All the communication 
functions are optional (Figure 4.17), please refer to communication connection 
instructions. 

Figure 4.17 Wi-Fi communication function

Internet

GPRS monitoring

Wi-Fi monitoring

Smart phone monitoring

PC monitoring

Web server

Router

Wi-Fi monitoring

Wi-Fi box

4. Installation

.19.

.18.

5.1 Start the Inverter

To start up the Inverter, it is important that the following steps are strictly followed:

1.  Switch the Supply Main Switch (AC) ON first.

2.  Switch the DC Isolator ON. If the voltage of PV arrays are higher than start up voltage, 

    the inverter will turn on. The red LED power will light, and the LCD shows the company's 

    name and the inverter model.

Solis-15K

Figure 5.1 Company Name and Inverter Model on LCD

3.  When both the DC and the AC grid sides supply to the inverter, it will be ready to 

    generate power. Initially, the inverter will check both its internal parameters and the 

    parameters of the AC grid, to ensure that they are within the acceptable limits.  At the 

    same time, the green LED will flash and the LCD displays the information of 

    INITIALIZING.

4.  After 30-180 seconds (depending on local requirement), the inverter will start to 

    generate power. The green LED will be on continually and the LCD displays 

    GENERATING.

WARNING: 

Do not touch the surface when the inverter is operating. It may be 
hot and cause burns.

5.2 Stop the Inverter

To stop the Inverter, the following steps must be strictly followed:

1.  Switch the Grid Supply Main Switch (AC) OFF.

2.  Wait 30 seconds. Switch off the DC switch or pull out the DC input cable. All the LEDs of 

    the inverter will be off in a minute.

Ginlong

5. Start & Stop

Summary of Contents for Solis-10K

Page 1: ...PV Grid Tie Inverter Installation and Operation Manual Ver 2 6 Solis Three Phase Inverter...

Page 2: ...ont Panel Display 3 2 LED Status Indicator Lights 3 3 Keypad 3 4 LCD 4 Installation 4 1 Selecting Location for the Inverter 4 2 Mounting the Inverter 4 3 Electrical Connections 5 Start and Stop 5 1 St...

Page 3: ...240V three phase grid system All 6 models are transformerless topology grid tie PV inverter Figure 1 1 Front side view 3 Figure 1 2 Bottom side view 6 Operation 6 1 Main Menu 6 2 Information 6 3 Sett...

Page 4: ...WARNING symbol indicates important safety instructions which if not correctly followed could result in serious injury or death Improper use may result in potential electric shock hazards or burns This...

Page 5: ...The inverter must be installed according to the instructions stated in this manual 5 The inverter must be installed according to the correct technical specifications 6 To startup the inverter the Gri...

Page 6: ...fault indications 8 9 To select a location for the inverter the following criteria should be considered To avoid over heating ambient air temperature MUST be considered when choosing the inverter ins...

Page 7: ...500mm 500mm 500mm 500mm Figure 4 1 Inverter Mounting clearance 4 Installation 4 Installation Inverter should be mounted in a vertical position as shown in Figure 4 3 The steps to mount the inverter on...

Page 8: ...itting the hooks into the slot of the bracket Use M4 14 stainless steel screws at holes E and F in Figure 4 to secure the mounting hooks to the rear of the inverter Figure 4 4 Wall Mount Bracket The e...

Page 9: ...4 8 Insert the Wire into the Connector Cap nut and contact pin Figure 4 10 Connector with Cap nut Screwed on Figure 4 11 Connect the DC Connectors to the Inverter v Then connect the DC connectors to t...

Page 10: ...of AC wire about 8mm Insert the cable through the jacket and cap nut of connector then insert the wires to the grid terminal and tighten the screws on the connector as shown in Figure 4 13 Please try...

Page 11: ...Solis 15K Figure 5 1 Company Name and Inverter Model on LCD 3 When both the DC and the AC grid sides supply to the inverter it will be ready to generate power Initially the inverter will check both i...

Page 12: ...n by scrolling up or down 6 Operation Pressing the ESC key returns to the Main Menu Pressing the ENTER key to lock Figure 6 2 a or unlock Figure 6 2 b the screen V_DC1 350 8V I_DC1 5 1A V_DC2 350 8V I...

Page 13: ...cation purpose The address number can be assigned from 01 to 99 see Figure 6 4 The default address number of Solis three phase inverter is 01 6 Operation 23 22 6 4 Advanced Info Technicians Only Selec...

Page 14: ...E Before to using this function please set GRID OFF to stop inverter refer to Section 6 5 2 NOTE The inverter is customized according to the local standard before shipping to the customer The User Def...

Page 15: ...ues of the User Def standard are some reference values They are not indicating the values of the standard you are currently using Press the UP DOWN keys to scroll through items Press the ENTER key to...

Page 16: ...Trouble Shooting Alarm Message OV G V UN G V OV G F UN G F G IMP NO GRID OV DC OV BUS UN BUS GRID INTF INI FAULT OV TEM GROUND FAULT Failure description Over grid voltage Under grid voltage Over grid...

Page 17: ...59 3 AS4777 VDE 0126 1 1 VDE 4105 CEI 0 21 CQC 31 30 9 Specifications Operating Range Utility Frequency Model The max DC input voltage MPPT operation range The max dc input current Number of MPPT stri...

Page 18: ...rent Rated grid frequency Max Efficiency Protection Size mm Weight Topology Internal consumption Running temperature Ingress protection Interface Design lifetime Utility Monitoring Operation Surroundi...