Main Features

√ 

Z-Ginger

® full-digital, highly reliable, large coverage, low power 

consumption internet of things wireless two-way network

√ 

With built-in 10/100M Ethernet, high stability and reliability

√ 

Support up 16 scenes, 64 devices, 128 bindings

√ 

Support all the smart home and alarm equipments with Z-Ginger® protocol

√ 

Backlit graph LCD screen

√ 

Universal quad-band GSM module (GW-9326)

√ 

Backlit high-sensitivity capacitive toch keyboard, support "wake-on-approach" 

function

√ 

8 user-definable touch key scenes

√ 

With bulit-in siren

√ 

Tamper alarm

√ 

Built-in Li-Ion rechargeable battery, ensure gateway working for 12 hours in the 

even of a power failure (GW-9325)

√ 

Support 1 gang external wired sensor input, 1 gang alarm output and 1 gang 

pulse output

√ 

Android/iOS/Windows multi-platform, multi-language APP

√ 

Devices fully configured in APP, simple and intuitive 

√ 

Built-in cloud service, all the equipment operations can be finished in cloud 

server

√ 

Adopt SSL/TLS encryption technology to implement cloud communication

√ 

Support cloud firmware upgrade

√ 

Support timing, sensors linkage trigger controlling

√ 

Support data backup and restore

√ 

Low battery notification of alarm sensors

√ 

Field voice monitoring (GW-9326)

  Local GSM call/SMS + APP push alarm notification

COM +12V PUSH SPK IN1

ON

OFF

RESET

GSM

12V1A

DC

Front side

Back side

1

2

3

4

5

6

7

8

9

0

Arm Scene

Arm Indicator

Scene3(At home)

Microphone

RESET key

"

COM

" is common port (negative terminal). "

IN1

" is 1 gang alarm sensor input, can connect 1 gang 

normally-open wired sensor; "

SPK

" is 1 gang wired siren output (active low, maximum sink current 

200mA); "

PUSH

" is 1 gang disarm unlock pulse output (active low), 500MS pulse will be sent out 

to control electic lock when gateway disarmed; "

+12V

" is 12V power output, can supply power for 

external wired sensor(maximum 200mA).  Please refer to the detailed connection method of terminals 

at page 9 "Addition"

Attention: "Programming jumper"is only used for maintenance, do not change its position.

Siren

Li-ion Battery Pack

7.4V 900mAh

RUN PROG

LCD screen

Disarm Scene

Disarm Indicator

Scene4(Go out)

Scene5(Get up)

Scene6(Pastime)

Scene7(Lunch)

Scene8(Sleep)

Backspace

Enter

Bracket hole

Standby battery

Tamper switch

Power switch
Programming jumper
Power adapter port

SIM card holder

Terminals 

Explanation of Gateway Appearance

1

2

ETHERNET

Ethernet interface

Summary of Contents for GW-9325

Page 1: ...Gingerway Technologies Co Ltd SmartC Ethernet Smart Gateway SmartC Ethernet Smart Gateway with GSM GW 9325 GW 9326 Instruction Manual Enjoy the Life 201804 V1 3 ...

Page 2: ...t curtain controller IR transmitter power strip alarm sensor etc Keywords Terminal Node The each gang light socket curtain alarm sensor and other devices which can be controlled by the smart gateway Binding Establish a secure connection between gateway and the terminal nodes Device Control Control the on off state and arm disarm state of single terminal node Scene The on off state and arm disarm s...

Page 3: ...kage trigger controlling Support data backup and restore Low battery notification of alarm sensors Field voice monitoring GW 9326 Local GSM call SMS APP push alarm notification COM 12V PUSH SPK IN1 ON OFF RESET GSM 12V1A DC Front side Back side 1 2 3 4 5 6 7 8 9 0 Arm Scene Arm Indicator Scene3 At home Microphone RESET key COM is common port negative terminal IN1 is 1 gang alarm sensor input can c...

Page 4: ...for 10 seconds the gateway will be restored to factory settings all data will be deleted except backup data The keys on the left and right columns of gateway panel are 1st to 8th scene of gateway Press Arm Scene key gateway will execute Arm scene all the alarm sensors which in this gateway will get into arm state If Arm scene executed successfully the gateway will make a long tone of Di and arm in...

Page 5: ... names all the alarm sensors will be automatically added into these two scenes The other scenes can be edited 5 6 At the gateway home interface of APP ZGinger Mini click the menu key in the top left corner will pop out the menu bar Click Edit can enter ino APP edit state you can view edit add delete the devices and scenes at edit state Click the gateway icon box at edit state can enter into Gatewa...

Page 6: ...e detection signals have no effect on trigger Set as ON indicates the trigger condition is that human body infrared or external trigger signals being detected Set as OFF indicates the trigger condition is human body infrared or external trigger signals not being detected You can also set the valid time and date for trigger according to your requirement 7 Tools Set Control Panel Icon User can use t...

Page 7: ...card is wrong Reinsert SIM card according to the identifier Power on before SIM card inserting Insert SIM card firstly then power on gateway The SIM card is not GSM standard Use the GSM standard SIM card Unable to login the gateway via Local The IP address used in login interface is different as the current gateway IP address Modify the IP address in login interface to the current IP address of ga...

Page 8: ...Xingye Industrial Park Zhongshanyuan No 2 Road Nanshan District Shenzhen Guangdong China Tel 0755 28779595 Fax 0755 28779405 Website www gingerway com Gingerway products are guaranteed for 2 years since the date of purchase During the warranty period if Gingerway products malfunction not contain artificial damages under normal circumstances they can be free repaired or exchanged at local dealer wi...

Reviews: