background image

11

Notice: Red Backlit is followed alarm temperature limit (Fever alarm) . 

•  Release the trigger and the reading will hold for approximately 15 seconds after 

which the meter will automatically shut off

 

Note

: Before shutting off, you can take further measurement.

•  If the temperature goes above 109.2°F or 42.9°C, Hi will appear in the display. 

  If the temperature goes below 89.6°F or 32.0°C, Lo will appear in the display.

Notice

: When surrounding temperature is lower than 10.0°C or higher 

than 40.0°C, it’s not allowed to measure of accuracy in not assured.

Object Temperature Measurements

•  Press the trigger to switch the meter on with one beeper. The device performs 

a brief self test: all elements of the display are shown for approx. 1 second. 

Following a successful self test with backlit (Red-Orange-Green).

• Press the “B/O” button for “Object temp” for accurate measurements in the 

range of 0.0 to 100.0°C (32.0 to 212.0°F).

•  Hold the meter by its handle and point it toward the surface to be measured.

• Press the trigger to take a temperature reading. The temperature reading ap-

pears in the display.

•  Release the trigger and the reading will hold for approximately 15 seconds after 

which thermometer will automatically shut off.

 

Note

: Before shutting off,you can take further measurements.

•  If the temperature goes above 212°F or 100°C, “Hi” will appear in the display. 

  If the temperature goes below 32°F or 0°C, “Lo” will appear in the display.

Notice:

•  The value under this Mode is object temperature instead of core temperature.

•  The defaulted infrared from the real temperature according to different emissiv-

ity. For example,the reading on stainless steel will be obviously lower than the 

actual temperature. BE CAUTIONS FOR SCALDING.

Data memory

• To review the logged data points, press the “Memory” button for one second 

while the units is ON until “M” symbol shown on the display. Use the + or - 

buttons to scroll through the stored measurements and memory locations. To 

delete all memory data, pls take off the batteries when power on. 

ENGLISH

Temperature (°C)

Temperature (°F)

Fever Teller

Beep

T < 32.0

T < 89.6

Green

Three beeps

32.0 ≤ T ≤ 37.5

89.6 ≤ T ≤ 99.5

Green

One beep

37.6 ≤ T ≤ 37.9

99.7 ≤ T ≤ 100.2

Orange

One beep

38.0 ≤ T ≤ 42.9

100.4 ≤ T ≤ 109.2

Red

Ten Rapid beeps

T > 42.9

T > 109.2

Red

Three beeps

Summary of Contents for YI-400

Page 1: ...N The operators must carefully read and completely understand the present manual before using the product AVIS Les op rateurs doivent lire et bien comprendre ce manuel avant d utiliser le produit ATEN...

Page 2: ...and use a damp swab to wipe the lens Do not use any solvents to clean the lens Measurement Notes If the meter has been stored in a cold or hot environment allow it at least 30 minutes to acclimate to...

Page 3: ...rature Mode settings With the meter ON press Mode button for three seconds until to F 1 shown to enter the long term calibration drift correction mode On entering the mode the previous temperature cor...

Page 4: ...d Press the trigger to switch the meter on with one beeper The device performs a brief self test all elements of the display are shown for approx 1 second Following a successful self test with backlit...

Page 5: ...re reading The temperature reading ap pears in the display Release the trigger and the reading will hold for approximately 15 seconds after which thermometer will automatically shut off Note Before sh...

Page 6: ...specific recycling point for electric and electronic equipment For further information on recycling points contact the local authorities the local recycling center or the shop where the product was pu...

Page 7: ...ctral response 8 to 14 um wavelength Display Backlit LCD display with function indicators Response time 500ms Over range indication Hi or Lo Operating Temperature Humidity 10 C to 40 C 50 F to 104 F 8...

Page 8: ...ents ES Precauci n lea las instrucciones advertencias cuidadosamente IT Dispositivo medico conforme alla Direttiva 93 42 CEE GB Medical Device complies with Directive 93 42 EEC FR Dispositif m dical c...

Reviews: