Congratulations on your purchase of our IR Thermometer. This thermometer is 

intended for scanning groups of individuals or monitoring an individual for ele-

vated temperatures. Always use a clinical thermometer when high accuracy body 

temperature measurements are required

Considerations and Warnings:

•  Read all instructions before using this product.

• For the most accurate results, make reading with an ambient (room) 

temperature of 10 to 40°C (50 to 104°F).

•  Make sure the skin is dry and that no hair interferes with the measurement.

•  Do not immerse the thermometer in water.

•  Avoid touching and/or scratching the infrared sensor lens.

• Always use a clinical thermometer to verify any abnormal temperature meas-

urements.

• Clean the lens area by gently blowing with compressed air and use a damp 

swab to wipe the lens. Do not use any solvents to clean the lens.

Measurement Notes

• If the meter has been stored in a cold or hot environment, allow it at least 30 

minutes to acclimate to room temperature before making measurements.

•  To prevent transmission of disease, avoid direct contact with the skin.

• After heavy exercise always wait at least 10 minutes before taking forehead 

temperature readings.

Storage and maintenance 

•  Clean the sensor tip after each use. Use a clean cloth or cotton bud that can be 

moistened with disinfectant, alcohol or warm water. 

•  To clean the entire device, please use a soft cloth slightly moistened with a mild 

soapy solution. 

•  Do not use any harsh cleaning products. 

•  If prolonged storage is intended, you should remove the battery. 

•  The device must not be stored or used at an excessively high or low tempera-

ture or humidity (see technical data), in sunlight, in association with an electrical 

current or in dusty locations. Otherwise inaccuracies can occur. 

Summary of Contents for YI-400

Page 1: ...N The operators must carefully read and completely understand the present manual before using the product AVIS Les op rateurs doivent lire et bien comprendre ce manuel avant d utiliser le produit ATEN...

Page 2: ...and use a damp swab to wipe the lens Do not use any solvents to clean the lens Measurement Notes If the meter has been stored in a cold or hot environment allow it at least 30 minutes to acclimate to...

Page 3: ...rature Mode settings With the meter ON press Mode button for three seconds until to F 1 shown to enter the long term calibration drift correction mode On entering the mode the previous temperature cor...

Page 4: ...d Press the trigger to switch the meter on with one beeper The device performs a brief self test all elements of the display are shown for approx 1 second Following a successful self test with backlit...

Page 5: ...re reading The temperature reading ap pears in the display Release the trigger and the reading will hold for approximately 15 seconds after which thermometer will automatically shut off Note Before sh...

Page 6: ...specific recycling point for electric and electronic equipment For further information on recycling points contact the local authorities the local recycling center or the shop where the product was pu...

Page 7: ...ctral response 8 to 14 um wavelength Display Backlit LCD display with function indicators Response time 500ms Over range indication Hi or Lo Operating Temperature Humidity 10 C to 40 C 50 F to 104 F 8...

Page 8: ...ents ES Precauci n lea las instrucciones advertencias cuidadosamente IT Dispositivo medico conforme alla Direttiva 93 42 CEE GB Medical Device complies with Directive 93 42 EEC FR Dispositif m dical c...

Reviews: