PROFESSIONAL MEDICAL PRODUCTS

PODOSCOPIO - PODOSCOPE

PODOSCOPE - PODOSCOPIO

PODOSCÓPIO - PODOSKOP  

Manuale d’uso 

User Manual  

Notice d’utilisation

Manual del usuario

Manual do utilizador 

Gebrauchs- und instandhaltungsanleitung

ATTENZIONE: 

Gli operatori devono leggere e capire completamente questo manuale prima di utilizzare il prodotto.

ATTENTION: 

The operators must carefully read and completely understand the present manual before 

using the product.

AVIS: 

Les opérateurs doivent lire et bien comprendre ce manuel avant d’utiliser le produit.

ATENCIÓN: 

Los operadores tienen que leer y entender completamente este manual antes de utilizar el producto.

ATENÇÃO: 

Os operadores devem ler e entender completamente este manual antes de usar o produto.

ACHTUNG:

 Diese Anleitung muss vor dem Einsatz des Produkts aufmerksam gelesen und vollständig 

verstanden werden.

M27363-M-Rev

.1.09.18

27363

Gima S.p.A.

Via Marconi, 1 - 20060 Gessate (MI) Italy

[email protected] - [email protected]

www.gimaitaly.com

Gima S.p.A.

Via Marconi, 1 

20060 Gessate (MI) Italy

Made in Italy

Summary of Contents for 27363

Page 1: ...efore using the product AVIS Les op rateurs doivent lire et bien comprendre ce manuel avant d utiliser le produit ATENCI N Los operadores tienen que leer y entender completamente este manual antes de...

Page 2: ...ence norms 17 1 5 Electrical features and voltage 18 1 6 Components identification 18 Electrical schema 19 1 7 General safety warning 19 Chapter 2 INSTALLATION 20 2 1 Transport and stocking 20 2 2 Con...

Page 3: ...USAGE MAINTENANCE Instructions for a correct installation are contained in the par 2 2 CONDITIONS FOR THE INSTALLATION Follow the instructions for use Read carefully this manual for the installation...

Page 4: ...an discover variations of colour intensity on the foot plant corresponding to higher or lower plant pressure The base is of ABS A separable net cable with plug a jack and a led strip are its electric...

Page 5: ...sports centres by operators with knowledge of biomechanics like doctors in sport medicine orthopedic specialists and physiotherapists Reference harmonized norms CEI EN 60601 1 Safety of electromedical...

Page 6: ...assembled and fixed in such a solid way so as to stand up to the often adverse transport conditions As to indirect shocks the device is classified in Class II As to current leakage it can be classifi...

Page 7: ...always take the following precautions A Always unplug the podoscope during maintenance operations B Do not move the podoscope while using it C Each time before the usage check the functioning of the c...

Page 8: ...ystyrene polyethylene cardboard must follow your local waste disposal guidelines 3 Verify that the podoscope has not been damaged during transport In case please contact the manufacturer immediately I...

Page 9: ...00 3 2 Voltage fluctuations flicker emissions IEC 61000 3 3 Compliance Group1 Class B Compliant Compliant Electromagnetic environment guidance The equipment 27363 must emit electromagnetic energy in o...

Page 10: ...ment Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment If the user of 27363 requires...

Page 11: ...the examination can be performed only if the patient is barefoot otherwise lay the caoutchouc on the transparent surface This material is also useful to check the validity of arch support treatments W...

Page 12: ...19 Then get out the blown fuse with a suitable instrument and replace it with a T 0 5 A 5x20 250V fuse If you have to replace the power cord the new one must have the same characteristics and certifi...

Page 13: ...he warranty GIMA will repair and or replace free of charge all the defected parts due to production reasons Labor costs and personnel traveling expenses and packaging not included All components subje...