5.4.
MetPak Range Mounting and Dimensions (in mm)
MetPak uses a mounting clamp suitable for attaching to a vertical pipe with a diameter of 30-
58mm. When mounting the MetPak, consider the position, orientation and alignment of the unit.
Note that the mounting pipe should first be degreased and when assembling the MetPak clamp
assembly the outer clamp nuts need to be tightened evenly to a torque figure of 3 Nm.
The moving plate part of the clamp needs to be reversed for poles below 38 mm diameter.
Mounting Bracket Assembly Exploded View
Mounting Bracket Assembled View
C Holes are 8.5mm diameter
Earthing Point for
supplied
screw/washer/tag