Gill Instruments Ltd
_____________________________________________________________________________________________________________
________________________________________________________________________________________________
MetPak/MetPak RG and MetPak Pro
Page | 10
Issue 1
Doc. No. 1723-PS-0022
October 2018
Inputs MetPak Pro (MetPak RG Digital Input only).
Analogue 1 (AN1)
0 to 5V or 4 to 20mA MetPak Pro powered or Analogue Sensor
Powered
Analogue 2 (AN2)
0 to 5V or 4 to 20mA MetPak Pro powered or Analogue Sensor
Powered
Analogue Input A-D
Conversion
12 bit resolution with an accuracy of
0.1% of reading, +35uV
offset (voltage inputs) or
0.5uA (current inputs).
Analogue Input Impedance
Input impedance for 0-5v input is 330 k ohm.
Input impedance for 4-20mA input is 47 ohms.
PRT
4 wire PRT, Pt100 conforms to IEC 60751
Digital Input (DIG1)
Rain Gauge
Contact Closure input (tipping bucket rain gauge) capable of
capturing events up to 10Hz
Digital Input
Capable of detecting an event with a duration of greater than
1.4mS.
Digital Input
Capable of detecting a space between events (i.e. terminals
open-circuit) with a duration of greater than 11mS.
Digital Input
Capable of reading a switch contact closure providing the total
Digital Switch contact resistance (contact and cabling) is less
than 1k ohm.
Outputs
Digital Outputs
RS232, RS422, *RS485 (*2 wire point to point) or SDI-12.
(RS232 point to point and RS485 2 wire networkable –
MODBUS RTU/ASCII)
Baud Rates
1200 (SDI-12), 4800-57600 (ASCII RS232, RS422, *RS485)
9600-19200 (MODBUS RTU/ASCII)
Protocols
ASCII, SDI-12 V1.3, NMEA 0183 (MetPak only) or MODBUS
RTU/ASCII
Data Output
1 reading per second (1 Hz), 1 reading per 2 seconds, 1
reading per 4 seconds or Polled Mode
MetPak Status
Status codes provided within the data message string
*
RS485 2 wire point to point only.
Power Supply
Input voltage (RS232, RS422,
RS485)
4.5v to 30v dc
Current at 12v
MetPak - 22mA
MetPak RG - 26mA
MetPak Pro - 26mA
Input Voltage SDI-12
9.6v to 16v dc (12v nominal)
Current
MetPak - 30mA
MetPak RG - 35mA
MetPak Pro - 35mA