8.1
Service for pedestrian doors
Warning:
Electrocution hazard! Before working on any live elements, pull
out the mains plug as well as any existing plug of the emergency
battery respectively switch off the main installation switch!
Check
Clean
2
Gr
ease
Adjus
t
Installation
General condition
x
Free door movement (manually)
x
x
Door guides/Bottom guide rail
x
x
x
Door sealing joints
x
x
x
Sliding door leaves/Side panels/Protection leaves
x
x
Coverings/hinge-type covers
x
x
Tight fitting of screws and nuts
x
Drive mechanism
Drive mechanism
x
x
x
Transmission elements such as:
Toothed belts, flat belts, cables, rods or chains
x
x
x
Running carriages with carrying pulleys and counter-pressure pulleys
x
x
x
Carrier rails
x
x
x
Open/Closed position
x
x
Control elements
All the existing control elements such as:
Detectors, radars, key-operated switches, contact carpets, etc.
x
x
x
Control unit
Electrical connections
x
Functions related to installation
x
x
Program switch functions
x
Emergency battery
x
Escape way doors
Emergency opening with mains failure
1
x
Opening speed 80 % in 3 seconds
1
x
x
Activation escape way detector 1,5 m in front of the door
1
x
x
Minimum escape way width
1
x
x
Maximum opening force at Break-Out leaf 220 N (1 m from floor)
x
x
Safety elements
Reversing/stopping mechanism
x
x
x
Door locking/Manual unlocking mechanism
x
x
x
x
Rubber cable
x
x
Monitoring switch
x
x
x
Light barrier/Presence detector
x
x
x
Safety according EN16005
Protections against impact
Protections against crushing
Protections against getting caught in
Protections against shearing
Protections against imprisoning
Safety deficiencies must be communicated to the operator (in writing)!
Miscellaneous
Rating plate, arrow sticker, glass sticker, etc. existing?
Control booklet existing and completed?
1
Only for redundant drive mechanisms.
2
Gilgen cleans all the elements of the installation provided this is necessary for the function of the installation. A general
cleaning of the installation is not planned.