background image

3/16" Pilot hole
required

#7

1/4-20

Spring Power Adjustment Screw
51(BF) Series Only

"BC" Valve

Pinion Cap

Closer
Size
Stamp

"L"Valve

"S"Valve

Standard Components

Optional Components

4

Closer Body

Co

ver

Sleeve Nut and Bolt

Thru Bolt and Grommet Nut

Drill 9/32 thru from Closer Side

3/8 Drill other side

Drill 

3/8 Drill other Side

9/32 thru from Closer Side

(Optional)

Metal

Wood

Top Jamb

Installation

See Page 5

289A Soffit Plate

Used with Parallel

Arm Closers Only

Soffit Plate

Regular Arm/Top

Jamb Shoe

Main Arm

Connecting Rod

Forearm
Screw

Arm Slide

Arm Assembly

214

Plate

"DL" suffix (Delayed Action) is an optional

feature. A separate sheet is supplied

showing closer adjustments.

NOTE:

  For special applications a separate 

door and frame preparation template is 
packed with these instructions. Use this 
instruction sheet for installation sequence 
and closer adjustments only.

Doors should be hung on ball bearing or 
anti-friction hinges.

A separate door stop is recommended.

Door and frame must be properly 
reinforced.

Adjust closing time speed between 3 and 7 
seconds from 90° to 0°.

These door closers should NOT be 
installed on the exposed side (weather 
side) of exterior doors.

Right Hand Door - RH
Left Hand Reverse - LHR

Left Hand Door - LH
Right Hand Reverse - RHR

Right Hand Door - RH
Left Hand Reverse - LHR

Right Hand Door - RH
Left Hand Reverse - LHR

Regular Arm

Installation

See Page 2

Left Hand Door - LH
Right Hand Reverse - RHR

Left Hand Door - LH
Right Hand Reverse - RHR

Top Jamb

Installation

See Page 5

Regular Arm

Installation

See Page 2

Parallel Arm

Installation

See Pages

3 & 4

Parallel Arm

Installation

See Pages

3 & 4

Machine Screws

#7 Drill, 1/4-20 Tap

Self Drilling Screws

Wood and Metal

For Wood drill 3/16 hole
      

CA

UTION

CA
UTION

An  Incorrectly  installed  or  improperly  adjusted 
door  closer  can  cause  property  damage  or 
personal  injury.  These  installation  instructions 
should  be  followed  to  avoid  the  possibility  of 
misapplication or misadjustment.

Installation Instructions

80-9350-2502-010 (05-12)

Non Hold Open Models

Sized

(Sizes 2,3,4,5,6)

52BC
53BC
54BC
55BC
56BC

Adjustable

(Sizes 3 thru 6)

51

(Sizes 1 thru 4)

51BF

Non Handed Door Closer

Tri-Pack 50 Series

Weaker

-

Stronger

+

Summary of Contents for Tri-Pack 51

Page 1: ...nd frame must be properly reinforced Adjust closing time speed between 3 and 7 seconds from 90 to 0 These door closers should NOT be installed on the exposed side weather side of exterior doors Right Hand Door RH Left Hand Reverse LHR Left Hand Door LH Right Hand Reverse RHR Right Hand Door RH Left Hand Reverse LHR Right Hand Door RH Left Hand Reverse LHR Regular Arm Installation See Page 2 Left H...

Page 2: ...101 to 120 121 to 180 7 178 6 152 3 1 2 89 Dimension A Door Wall Hardware Jamb conditions permitting Right Hand Shown BC L S L S 51 BF Only Spring Power Adjust If Necessary A B F 90 E D Inches mm 2 PA 2 or 50 Series G Pinion Cap or Optional Cover Caution Don t completely close valve Optional Cover C L Y S Z R L S Stronger Weaker Slower Faster Faster Slower Stronger Weaker ...

Page 3: ... 3 4 197 5 3 4 146 B 7 5 8 194 6 1 8 156 4 1 8 105 C 8 5 8 219 7 1 8 181 5 1 8 130 1 9 1 2 3 4 70 3 8 10 1 2 13 7 16 11 2 50 A 1 1 2 38 7 178 4 102 2 1 8 54 3 1 4 83 1 2 13 3 4 19 9 1 16 230 C L C B Top of Door Door Wall Hardware Jamb conditions permitting Inches mm 5 3 S L Place Arm on Spindle Rotate Remove Arm from Spindle Close Valves L S Latch Sweep Optional Cover See Step 6 on Page 4 Frame Sl...

Page 4: ... Adjust 51 BF only If necessary PA BC S L S L 1 1 2 38 4 or 2 Assemble Arm Arm Screw Open Valves Caution Don t completely close valve Pinion Cap or Optional Cover L Y S Z R L Y S Z R Left Hand Door Right Hand Door or B A Flat Flat Slower Faster Weaker Stronger Stronger Weaker Slower Faster Caution Do Not Back Valve Out Completely ...

Page 5: ...6 152 3 1 2 89 Dimension A Door Wall Hardware Jamb conditions permitting Right Hand Shown BC L S L S 51 BF Only Spring Power Adjust If Necessary 90 Top of Door Inches mm 5 D B A E F PA G Parts Caution Don t completely close valve A longer connecting rod is required for reveals greater than 3 76 or Pinion Cap or Optional Cover Optional Cover Reveal C L Y S Z R Stronger Weaker Slower Faster Faster S...

Page 6: ...10 13 5 7 10 14 16 NOT RECOMMENDED USE 51 18 FULL 360 TURNS MAXIMUM AVAILABLE MAXIMUM DOOR SIZE Number of Turns Required Date Code or or 7 1 2 Stronger 7 1 2 Weaker Use 3 16 Hex Wrench for this Adjustment Use 1 8 Hex Wrench for these Adjustments Stronger Weaker Slower Faster Faster Slower Stronger Weaker 3 6 BE Size Code An ASSA ABLOY Group brand 3000 Highway 74 East Monroe NC 28112 Tel 800 438 19...