- With the aid of the special tool, loosen the impel-
ler shaft turning the spanner clockwise (left-hand-
ed thread)
- As the thread is fully disengaged, extract the
shaft with the aid of pliers.
Specific tooling
020169Y
Water pump crankshaft fitting and re-
moval spanner
- Using the special hook, remove the sealing ring from its housing as shown in the picture.
Specific tooling
020209Y
Spring hook
Thermostat
Removal
•
Detach the coolant hose from the
head, partially draining the system.
•
Remove the cylinder head.
•
Remove the two fixing screws and
hence the thermostat.
Check
1) Visually check that the thermostat is not dam-
aged.
2) Fill a metallic container with approx. 1 litre of
water.
Immerge the thermostat, and keep it in the centre
of the bowl.
Immerge the multimeter temperature probe, and
keep it close to the thermostat.
Heat up the bowl using the thermal gun.
Check the thermostat opening start temperature:
Heat up until the thermostat is completely open.
DNA 50
Cooling system
COOL SYS - 111
Summary of Contents for DNA 50
Page 1: ...WORKSHOP MANUAL 633507 DNA 50 ...
Page 4: ......
Page 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 16: ...INDEX OF TOPICS TOOLING TOOL ...
Page 25: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 35: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL ...
Page 41: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 58: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 60: ...Engine from vehicle DNA 50 ENG VE 60 ...
Page 61: ...INDEX OF TOPICS ENGINE ENG ...
Page 92: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 99: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 107: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Page 113: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 121: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Page 125: ...INDEX OF TOPICS TIME TIME ...