MDE-5491A
18
SECTION 4 - INSTALLATION
4
Cables
To connect the cables:
1
Connect all cable connections from the electronics on the 10.4-inch display E-CIM door. The following
are the cable connections:
• M14346 video cable from UPM to PIP3
• M14340 Power Cable to PIP3, UPM, and card reader
• M14339 Serial Cable from PIP3
• M14338A001 and M14425A001 Applause Media System Cables (if present) from UPM and PIP3
• Speaker or intercom cable (if present) from PIP3
• USB cable from UPM to PIP3
• USB cable from printer
• Ethernet cables from UPM and card reader
• M13119 Cable from door node
Figure 2: Printer Cable Connection for Alphanumeric Door
Connect the 24 V power
cable from the printer to
the power supply board
Connect the USB cable
from the printer to PIP3
Connect the printer ground
cable to the U-Channel ensuring
to keep it separated from the
printer 24 V power cable