SECTION 4 - INSTALLATION
4
MDE-5491A
E-CIM
To install the E-CIM door:
1
Carefully mount the E-CIM on the door.
Note: Ensure that the E-CIM gasket seals properly against the door bezel.
2
Insert all 1/4-inch thread-forming screws to mount the E-CIM to the door removed in step
including the 1/4-inch thread-forming screws to connect the PPU bracket at the bottom of the E-CIM.
3
Insert and tighten the five Phillips-head screws in the top row on the front of the unit.
Figure 1: E-CIM Mounting Screws
E-CIM Mounting
Screws (5X)
4
Install the PPU graphic (including adhesive and white adhesive tape).
5
Install the grade select buttons.
6
Remount the door node.
Note: If you are working on both doors, ensure that you remount the door node to the same side from
which it was removed.
7
Install card reader, display, and, if present, contactless, 2D scanner, speaker.