location on the bottom of the switch.
2. Set the switch on a desktop or any other flat surface; for proper ventilation,
make sure that the switch has at least 2 inches of space on each side and
5 inches of space at the back. It is very important that the fans located in
the rear panel are not blocked.
◘
Caution: Restricted airflow could cause overheating of the components.
3-c Desktop Installation
Installation Site Preparation
You can mount EtherEngine2400-G Gigabit Ethernet Switch either on a table
or on a standard-size rack. If you plan to mount the switch on the table,
please choose a steady, level surface in a well-ventilated area that is free
from excessive dust. In any case, the installation site chosen for your switch
has to comply with the following requirements:
The surface where you want to mount the switch must be able to sustain
at least 3.8kg.
Do not place heavy objects on top of the switch
The location must preferably be free from excessive dust, away from
heat vent or other warm-air exhaust and direct sunlight. The switch
should not be placed near large electric motors or other electromagnetic
equipments. As a reference, the strength of the electromagnetic field on
site should not exceed the (RFC) standards for IEC 801-3, Level 2 (3V/M)
field strength.
The air temperature in the location should be within a range of 32
˚
F to
122
˚
F (0
˚
C to 55
˚
C).
The relative humidity in the location should not exceed 95%
non-condensing humidity.
The power outlet should be located within 6 feet from the device.
The distance between the RJ-45 port and the standard network interface
should not exceed 100 meters.