System Hardware Installation
- 28 -
3-4 Removing and Installing the Heat Sink
Read the following guidelines before you begin to install the heat sink:
• Always turn off the computer and unplug the power cord from the power outlet before installing
the heat sink to prevent hardware damage.
• Unplug all cables from the power outlets.
• Disconnect all telecommunication cables from their ports.
• Place the system unit on a flat and stable surface.
• Open the system according to the instructions.
WARNING!
Failure to turn off the server before you start installing components may cause serious damage. Do
not attempt the procedures described in the following sections unless you are a qualified service
technician.
Follow these instructions to install the heat sink:
1. Loosen the screws securing the heat sink in place in reverse order (4
g
3
g
2
g
1).
2. Lift and remove the heat sink from the system.
3. To install the heat sink, reverse steps 1-2 while ensuring that you tighten the captive screws in
sequential order (1
g
2
g
3
g
4) as seen in the image below.
1
3
1
2
4
• When installing the heatsink to CPU, use PHILLIPS #2-Lobe driver to tighten 4 captive nuts in
sequence as 1-4. The screw tightening torque: 14 ± 0.5 kgf-cm (30.0± 1.0 lbf-in).
Summary of Contents for S461-3T0
Page 1: ...S461 3T0 4U 60 Bay Dual Processors Storage Server User Manual Rev 1 0 ...
Page 10: ... 10 This page intentionally left blank ...
Page 13: ... 13 Hardware Installation ...
Page 16: ... 16 Hardware Installation 1 3 System Block Diagram ...
Page 20: ...System Appearance 20 ...
Page 35: ... 35 System Hardware Installation 3 4 6 5 ...
Page 42: ...This page intentionally left blank ...
Page 46: ... 46 Motherboard Components This page intentionally left blank ...
Page 66: ...BIOS Setup 66 5 2 11 Intel R I210 Gigabit Network Connection ...
Page 68: ...BIOS Setup 68 5 2 12 VLAN Configuration ...