5 - SET-UP FOR OPERATION
009_03
- GAS FRY TOP
5.1.15 Setting reduced capacity power
The minimum setting screw (pos. 20 fig. 3) should be adjusted as fol-
lows:
• for operation with LPG it should be screwed all the way down;
• for operation with methane, use the gas flow table to check the
value in l/min with respect to the operating alorific value (meas-
urement in accordance with the volumetric method). Start the
appliance in accordance with the instructions. Turn the knob to
the minimum position and use screw (pos. 20 fig. 3) to adjust the
flow (clockwise = flow reduction; conter-clockwise = flow
increase).
Fot the models SKT2G2/GC2/GR2/GLR - TT2G2/GC2/GR2/GLR -
CFTG22/G2C2/G2R2/G2LR - SKT60G2/GC2/GR2/GLR -
TT60G2/GC2/GR2/GLR - CFTG62/G6C2/G6R2/G6LR - SKT3G/GC/GLR -
TT3G/GC/GLR - CFTG3/G3C/G3R/G3LR - SKT80G/GC/GLR -
TT80G/GC/GLR - CFTG8/G8C/G8R/G8LR each burner must be adjusted
separately.
5.2 Maintenance
Attention! Before doing any repair or maintenance
work, unplug the appliance.
The following maintenance program should be carried out at least
once a year by qualified personnel with license:
• Check that all the safety and adjustment devices are working
properly;
• Check that the burners are working properly with regard to:
- ignition
- combustion safety;
Check functioning of the appliance as described in paragraph 5.1.6
“Operation control”.
5.3 Replacing parts
All parts must be replaced by authorized technicians
only!
To replace the following parts first remove all the control knobs and
control panel (after loosening the fixing screws), then extract the
ignition wire.
5.3.1 Gas cock
Loosen the gas piping (pos. 21,16,17,18 fig. 3) and thermocouple
hoses, then loosen the fixing screws and insert a new cock. After the
replacement check the seal using a leack detetctor spray.
5.3.2 Gas valve
Loosen the gas piping (pos. 21,16,17,18 fig. 2) and thermocouple
hoses, then loosen the fixing screws and insert a new valve. After
the replacement check the seal using a leack detetctor spray.
5.3.3 Thermocouple
Loosen the nipples fixing the thermocouple to the gas cock/ gas
valve and to the pilot burner; insert the new part. After replacing
the parts, fit the control panel and its parts back in the right order.
5.3.4 Ignition plug
The ignition plu (pos. 37 fig. 6) must be removed from below.
Disconnect the ignition lead, loosen the lock nut and insert a new
plug.
5.3.5 Ignition plug fry top 2 controls 600
The ignition plu (pos. 37 fig. 7) must be removed from below.
Disconnect the ignition lead, loosen the lock nut (pos. 38 fig. 7) and
insert a new plug.
After any maintenance or repair work, replace the con-
trol panel and the lower panel.
After replacing gas input components, check operation
again and test for leakage.
14
· 20
35
36
34
29
37
Fig. 6
11
13 12
27
38
37
Fig. 7