3-7-4 Intel Optane DCPMM DIMM Population Rule
Thermal conditions for DCPMM DIMM support:
•
The ambient temperature must be at or below 35°C
•
The Cascade Lake CPU used must have a maximum TDP of 205W
•
A maximum of 12 pcs 256G DCPMM may be installed
• RDIMM / DCPMM must be installed into CPU0 memory first
•
You must install one RDIMM into any slot #0 of CPU0 before installing the DCPMM.
(e.g. A0/B0/C0/D0/E0/F0)
•
The DCPMM must be installed into the DIMM slot #1 next to the corresponding RDIMM
in slot #0 (e.g. if RDIMM is installed into DIMM slot A0, the DCPMM must be installed into
DIMM slot A1)
P0_D0/RDIMM Slot
P0_D1/Intel Optance DCPMM Slot
P0_E0/RDIMM Slot
P0_E1/Intel Optance DCPMM Slot
P0_F0/RDIMM Slot
P0_F1/Intel Optance DCPMM Slot
P0_C1Intel Optance DCPMM Slot
P0_C0/RDIMM Slot
P1_L0/RDIMM Slot
P1_L1/Intel Optance DCPMM Slot
P1_K0/RDIMM Slot
P1_K1/Intel Optance DCPMM Slot
P1_J0/RDIMM Slot
P1_J1/Intel Optance DCPMM Slot
P0_B1Intel Optance DCPMM Slot
P0_B0/RDIMM Slot
P0_A1/Intel Optance DCPMM Slot
P0_A0/RDIMM Slot
CPU0
CPU1
P1_G1/Intel Optance DCPMM Slot
P1_G0/RDIMM Slot
P1_H1/Intel Optance DCPMM Slot
P1_H0/RDIMM Slot
P1_I1/Intel Optance DCPMM Slot
P1_I0/RDIMM Slot
Summary of Contents for G591-HS0
Page 1: ...G591 HS0 HPC Server 5U 32 x PCIe GPU Server User Manual Rev 1 0 ...
Page 10: ...This page intentionally left blank ...
Page 15: ... 15 Hardware Installation 1 3 System Block Diagram ...
Page 16: ...This page intentionally left blank ...
Page 22: ...System Appearance 22 This page intentionally left blank ...
Page 31: ... 31 System Hardware Installation 5 6 1 2 3 4 CPU0 CPU1 ...
Page 40: ... 40 System Hardware Installation This page intentionally left blank ...
Page 44: ...Motherboard Components 44 This page intentionally left blank ...
Page 65: ... 65 BIOS Setup 5 2 12 Intel R X722 Gigabit Network Connection ...
Page 67: ...BIOS Setup 67 5 2 13 VLAN Configuration ...
Page 71: ...BIOS Setup 71 5 3 1 Processor Configuration ...