![GIESSE VARIA SLIM BASE Instruction And Installation Manual Download Page 19](http://html.mh-extra.com/html/giesse/varia-slim-base/varia-slim-base_instruction-and-installation-manual_2222426019.webp)
19
Model
VARIA SLIM 230V
VARIA SLIM 24V
VARIA SLIM
SYNCRO 230V
VARIA SLIM
SYNCRO 24V
Electrical insulation
Class II
Class III (Selv)
Yes
Low tension
Type of service (DR)
2 cycles
5 cycles
Operating temperature
- 5 + 65 °C
- 5 + 65 °C
Protection index for electrical devices
IP30
IP30
Adjustment of connection to window frame
Automatic definition of position
Automatic definition of position
Parallel powering of two or more motors
Yes (max 20)
Yes (max 10)
Yes
Yes
Synchronised function
No
Yes (max 8)
Yes
Yes
Holding nominal force (it can vary according to the chosen brackets)
1600 N
1600 N
Stroke-end at opening
Electronic with regulation by means of dip-
switches
Electronic with regulation by means of dip-
switches
Stroke-end at closing
At absorption of power
At absorption of power
Signalling ‘window open/window closed’
No
No
No
No
Length of power cable
2 m
2 m
2,5 m
2,5 m
Dimensions
386,5x59x37 mm
386,5x59x37 mm
Weight (Kg)
0,980
0,970
1,180
1,150
Any information reported in this table is not binding and may be susceptible to variations without notice.
7. ID PLATE AND MARKING DATA
Actuators have CE marking and comply with the Standards listed in the Declaration of Conformity. They also come with a Declaration of
Incorporation, due to their classification by the Machinery Directive as “partly completed machines”. Both declarations are included in the final pages
of this manual.
The plate data is displayed on an adhesive label placed on the outside of the casing, which must remain intact and visible. The main information it
displays includes: manufacturer's address, product name - model number, technical characteristics, production date and serial number.
In the event of a complaint, please indicate the serial number (SN) displayed on the label. An explanation of the symbols used on the label to
abbreviate the technical characteristics is given in the table in the c
hapter on “TECHNICAL DATA”.
8. ELECTRICAL POWER SUPPLY
The Series VARIA SLIM actuator is commercially available in four versions identified according to electrical specifications:
1.
VARIA SLIM 230VAC
: runs on grid tension of 230V~ (a.c.), 50Hz (±10%), with a three wire cable
(L
IGHT
B
LUE
, common neutral; B
LACK
,
phase open; B
ROWN
, phase closed)
.
2.
VARIA SLIM SYNCRO
230VAC
: runs on grid tension of 110/230V~ (a.c.), 50/60Hz (±10%), with a five wire cable
(L
IGHT
B
LUE
, common
neutral; B
LACK
, phase open; B
ROWN
, phase closed)
. The additional wiring (
R
ED
and
W
HITE
) is for electronic synchronisation (patented).
3.
VARIA SLIM 24VDC
: runs on 24V═ (d.c.), with three wire cable,
R
ED
“1”, connected to the + (positive) closes; B
LACK
“2”, connected to the
+ (positive) opens
. A third wire
G
REEN
“3”,
is used for the possible connection to the electromechanical lock.
4.
VARIA SLIM SYNCRO
24VDC
:
runs on 24V═ (d.c.), with five wire cable,
B
LACK
“1”, connected to the + (positive) closes; B
LACK
“2”,
connected to the + (positive) opens
. The third wire
B
LACK
“3”,
is used for the possible connection to the electromechanical lock. The
additional wiring (
R
ED
and
W
HITE
) is for electronic synchronisation (patented).
Low tension actuators 24V═ (d.c.) can be powered using a feeder with an output tension of 24V═ (d.c.)
(-15% ÷ +20%, or min. 20.4V, max. 28.8V)
. The
feeder must be approved and class II
(double safety insulation)
.
8.1.
Selection of power cable section
In low tension supply systems, tension falls due to current passage in conductors is a basic aspect for safety and good appliance function. It is
therefore extremely important that the conductor section in function of cable length is calculated correctly. The following table indicates cable lengths
for an actuator connected at nominal charge.
CABLE SECTION
Actuator fed at
24V
110V~
230V~
0.50 mmq
~20 m
~300 m
~1400 m
0.75 mmq
~30 m
~450 m
~2100 m
1.00 mmq
~40 m
~600 m
~2800 m
1.50 mmq
~60 m
~900 m
~4000 m
2.50 mmq
~100 m
~1500 m
~6800 m
4.00 mmq
~160 m
~2500 m
~11000 m
6.00 mmq
~240m
~3700 m
~15000 m
9. INSTRUCTIONS FOR ASSEMBLY
These indications are for specialised technical personnel and basic work and safety techniques are not indicated.
All preparatory, assembly and electrical connection operations must be performed by specialised technical personnel to guarantee optimal function
and service of the actuator.
Check that the following fundamental conditions have been met:
Before installing the actuator, check that the moving parts of the window on which it is to be installed are in perfect working condition and
that they open and close properly and are well balanced (where applicable).
Actuator specifications must be sufficient for movement of the window without encountering any obstacle. The limits indicated in the technical
data table must not be superseded
(sec. 6)
and the most appropriate stroke should be selected. Calculations should be checked using the
formula indicated on section 3.1.
Attention. Check that the electrical power supply corresponds to that indicated on the TECHNICAL DATA label on the machine.
Ensure that the actuator has not been damaged during transport, first visually and then by powering in both
directions.
Check that the width of the inside of the window (where the actuator is to be assembled) is over 405 mm,
otherwise the actuator should not be installed.
Check that once the actuator has been installed the distance between the fixed part of the window frame (where
the actuator is to be assembled) and the mobile part of the window frame (where the bracket is to be fixed) is
greater than or equal to 0 mm (Fig. 1). If this is not the case the actuator will not function correctly as the window
will not close correctly. If required, add additional thickness below the support brackets to reset the quota.
Figure 1