41
IMPORTANT FOR PRODUCT SAFETY
: in synchronized motors with power supply
voltage 24V
, if not used, the
G
REEN
wire
must be insulated
.
9.1.
Power supply cable cross-sections
The table below shows the maximum cable length for the connection of a single actuator.
CABLE CROSS-
SECTION
Actuators operating on
24V
110V~
230V~
0.50 mm²
~20 m
~300 m
~1400 m
0.75 mm²
~30 m
~450 m
~2100 m
1.00 mm²
~40 m
~600 m
~2800 m
1.50 mm²
~60 m
~900 m
~4000 m
2.50 mm²
~100 m
~1500 m
~6800 m
4.00 mm²
~160 m
~2500 m
~11000 m
6.00 mm²
~240m
~3700 m
~15000 m
10. ACTUATOR ASSEMBLY INSTRUCTIONS
These instructions are intended for technical and specialized personnel, therefore
basic safety and working techniques are not discussed.
All operations for preparation, assembly and electrical connection must be carried out by
technical and specialized personnel; this will guarantee optimum performance and proper
operation of the actuator. First of all, ensure that the following basic requirements are met:
Before installing the actuator, check that the moving parts of the window or door on
which it is to be installed are in excellent mechanical condition, that they open and
close correctly, and that they are well balanced (where applicable).
The actuator's power must be sufficient to move the window; the limits indicated in
the product technical data table (par. 6) cannot be exceeded. A rough calculation
can be made using the formula provided in paragraph 2.1 of this manual.
Attention:
check that the device has the same type of power supply as the one
available at connection, by checking the data on the label attached to the
gearmotor.
Make sure that the actuator has not been damaged during transport, first visually
and then by powering it in one direction and the other.
On bottom-hung windows, there is the risk of injury if the window accidentally falls.
A compass limit stop or an alternative safety system, calculated to prevent the
window from accidentally falling, must be installed.
10.1.
Preparing for assembly
Before starting assembly of the actuator, prepare the following accessory materials,
equipment and tools.
◆
Installation on metal windows: M5 threaded inserts
(6 pieces)
, M5x12 flat headed metric
screws
(6 pieces)
.
◆
Installation on wooden windows: self threading screws for wood Ø4.5
(6 pieces)
.
Summary of Contents for RACK MAX 650
Page 10: ...10 A 70 A RU...
Page 60: ......
Page 111: ...111 2 2 1 F P C H F 0 54 x P A B F 0 54 x P x C H...
Page 112: ...112 2 2 3 4 RACK MAX 650 3...
Page 118: ...118 B 2 C 3 3bis D 4 E 5 5bis F G 6 H M6x25 10 I 4 5 J K 10 4 10 3 10 5 RACK MAX 650...
Page 123: ...123 12 12 3 DIP DIP ON DIP OFF 1 TUBE LOCK TUBE LOCK 12 1 TUBE LOCK DIP 5...
Page 124: ...124 DIP OFF TUBE LOCK DIP TUBE LOCK 8 5 1 1 1 2 2 2 TUBE LOCK 12 2...
Page 125: ...125 12 3 10 11 3 12 4 DIP 1...
Page 126: ...126 2 3 4 5 6 7 8 9 10 11...
Page 127: ...127 0 5 3 13 5...
Page 128: ...128 10 1 14 1 2 10 3 4 1 2 15...
Page 129: ...129 16 17 1490 2...
Page 130: ...130...
Page 134: ...134 2006 42 EC 6 2021 GIESSE S p A...
Page 136: ...136 2006 42 EC 6 2021 GIESSE S p A...